Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.uan.edu.co/handle/123456789/1971
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMoreno López, Deywis-
dc.contributor.advisorRodriguez Suarez, Cesar Augusto-
dc.contributor.advisorHernández, Andrés Ignacio-
dc.creatorDelgado Gonzalez, Maritza Juliette-
dc.date.accessioned2021-02-26T14:01:41Z-
dc.date.available2021-02-26T14:01:41Z-
dc.date.created2020-11-24-
dc.identifier.urihttp://repositorio.uan.edu.co/handle/123456789/1971-
dc.descriptionExternaes_ES
dc.description.abstractAt the moment, there is no dosimeter that provides a real-time measurement of ultraviolet radiation dose at cryogenic temperatures during the sterilization of liquid nitrogen, because the technical parameters are defined at room temperature, and many of these change dramatically at temperature of -195 °C. In this work, a prototype of a cryogenic dosimeter based on Silicon photomultipliers (SiPM) is designed, useful for characterizing the dose of ultraviolet radiation measured in real time for quality control of cryogenic applications in medicine, biology, biotechnology and industry. In this study, a simulation with optical photons (253 nm) was performed in liquid and gaseous nitrogen, using Geant4 simulation toolkit. The results present a zone of minimal UV radiation inside a container of liquid nitrogen, and a method for estimating the radiation dose with one or more cryogenic SiPMs, located inside the container, especially in the minimum radiation zone in order to certify the absence of microorganisms in the liquid nitrogen.es_ES
dc.description.sponsorshipOtroes_ES
dc.description.tableofcontentsEn la actualidad, no es posible encontrar un dosímetro que proporcione una medida de la dosis de radiación ultravioleta en tiempo real a temperatura criogénica durante la esterilización del nitrógeno líquido, ya que sus parámetros técnicos se definen a temperatura ambiente, y muchos de estos cambian drásticamente a una temperatura de -195°C. En este trabajo se diseña un prototipo de un dosímetro criogénico basado en fotomultiplicadores de Silicio (SiPM), útil para la caracterización de la dosis de radiación ultravioleta medida en tiempo real para controles de calidad en aplicaciones criogénicas en medicina, biología, biotecnología e industria. En este estudio se realizó una simulación con fotones ópticos (253 nm) en nitrógeno líquido y gaseoso, utilizando el kit de herramientas de simulación Geant4. Los resultados presentan una zona de mínima radiación UV dentro de un contenedor de nitrógeno líquido y un método para la estimación de la dosis de radiación con uno o más SiPM´s criogénicos ubicados dentro del contenedor, especialmente, en la zona mínima de radiación con el fin de certificar la ausencia de microorganismos dentro del nitrógeno líquido.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.subjectRadiación Ultravioleta, Nitrogeno Líquido, Esterilización, Silicon Photomultiplier, Geant4es_ES
dc.titleSistema y método para estimar la dosis de radiación ultravioleta durante la esterilización del nitrógeno líquidoes_ES
dc.publisher.programDoctorado en Ciencia Aplicadaes_ES
dc.rights.accesRightsrestrictedAccesses_ES
dc.subject.keywordUltraviolet Radiation, Liquid Nitrogen, Sterilization, Silicon Photomultiplier, Geant4es_ES
dc.type.spaTesis y disertaciones (Maestría y/o Doctorado)es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.source.bibliographicCitationAbi, B. e. (2020). Introduction to DUNE. Journal of Instrumentation, Volume 15.es_ES
dc.source.bibliographicCitationAbi, B. e. (2020). The DUNE far detector single phase technology. Journal of Instrumentation, Volume 15.es_ES
dc.source.bibliographicCitationAcciari, R. e. (2011). Test and Comparison of Photomultiplier Tubes at Liquid Argon Temperature. Technology and Instrumentation for Particle Physics., 1087-1094.es_ES
dc.source.bibliographicCitationAcciari, R. e. (2017). Design and Construction of the MicroBooNE Detector. Journal of instrumentation.es_ES
dc.source.bibliographicCitationAcerbia, F., & Gundackerbc, S. (2019). Understanding and simulating SiPMs. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 16-35.es_ES
dc.source.bibliographicCitationAgostinelliae, S., & Allisonas, J. (2003). Geant4 a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 250-303.es_ES
dc.source.bibliographicCitationÁlvarez, V. e. (2012). NEXT-100 Technical Design Report (TDR). Executive summary. Journal of instrumentation, Vol 7.es_ES
dc.source.bibliographicCitationBakkali, J., Doudouh, A., & Mansouri, H. (2018). Assessment of Monte Carlo Geant4 capabilities in prediction of photon beam dose distribution in a heterogeneous medium. Physics in medicine, 1-5.es_ES
dc.source.bibliographicCitationBerra, A. e. (2015). A SiPM based real time dosimeter for radiotherapic beams. Nuclear Instruments and Methods in Physics Research A, 72-80.es_ES
dc.source.bibliographicCitationBielanski, A. e. (2003). Microbial contamination of embryos and semen during long term banking in liquid nitrogen. Cryobiology, 146-152.es_ES
dc.source.bibliographicCitationBirmpa, A., Sfika, V., & Vantarakis, A. (2013). Ultraviolet light and Ultrasound as non-thermal treatments for the inactivation of microorganisms in fresh ready-to-eat foods. International Journal of Food Microbiology, 96-102.es_ES
dc.source.bibliographicCitationBoullard, A., & Giacomoni, P. U. (1988). Effect of UV irradiation at defined wavelengths on the tertiary structure of double-stranded covalently closed circular DNA. Journal of Photochemistry and Photobiology B: Biology, 491-501.es_ES
dc.source.bibliographicCitationCervi, T. e. (2017). Study oSiPM custom arrays for scintillation light detection in a Liquid Argon Time Projection Chamber. Journal of Instrumentation, Volume 12.es_ES
dc.source.bibliographicCitationChang, J. C., & et al. (1985). UV Inactivation of Pathogenic and Indicator Microorganisms. Applied and environmental microbiology, 1361-1365.es_ES
dc.source.bibliographicCitationElder, K., Bergh, M. V., & Woodward, B. (2015). Troubleshooting and problem-Solving in the IVF Laboratory. United Kingdom: Cambridge University Press.es_ES
dc.source.bibliographicCitationEPA, A. U. (2003). Ultra Violet Disinfection Special Manual. U.S.Environmental Protection Agency. Washington: EPA 815-D-03-007.es_ES
dc.source.bibliographicCitationFalcone, A. e. (2020). Cryogenic SiPM arrays for the DUNE photon detection system. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1646-1648.es_ES
dc.source.bibliographicCitationGerba, C. P., Gramos, D. M., & Nwachuku, N. (2002). Comparative Inactivation of Enteroviruses and Adenovirus 2 by UV Light. Applied and Environmental Microbiology, 5167-5169.es_ES
dc.source.bibliographicCitationGrace, E., & et al. (2017). Index of refraction, Rayleigh scattering length, and Sellmeier coefficients in solid and liquid argon and xenon. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 204-208.es_ES
dc.source.bibliographicCitationGriesmann, U., & Burnett, J. (1999). Refractivity of nitrogen gas in the vacuum ultraviolet. Optics Letters, 1699-1701.es_ES
dc.source.bibliographicCitationGutiérrez, A., López, M. A., Palou, E., & Ramirez, C. N. (2015). Métodos para la determinación de la dosis de radiación ultravioleta de onda corta (UVC) en alimentos. Temas selectos de Ingeniería de alimentos, 34-40.es_ES
dc.source.bibliographicCitationHurst, C. J. (2017). Modeling the Transmission and Prevention of infectious Desease. USA: Springer.es_ES
dc.source.bibliographicCitationINVIMA. (2009). Manual de buenas practicas de Manufactura de los Gases Medicinales. Bogotá: Ministerio de Salud y Protección Social de Colombia.es_ES
dc.source.bibliographicCitationIsachenko, V. e. (2010). Human ovarian tissue cryopreservation: quality of follicles as a criterion of effectiveness. Reproductive BioMedicine, 441-442.es_ES
dc.source.bibliographicCitationISO14161. (2000). esterilización de productos sanitarios : indicadores biológicos : orientación para la selección, la utilización y la interpretación de los resultados. AENOR.es_ES
dc.source.bibliographicCitationJoaquim, D. C., Borges, E. D., Viana, L. G., Navarro, P. A., & Vireque, A. A. (2017). Risk of Contamination of Gametes and Embryos during Cryopreservation and Measures to Prevent Cross-Contamination. BioMed Research International, 11.es_ES
dc.source.bibliographicCitationKryczynski, P. e. (2016). Scintillation light detection system in LArIAT. Journal of Instrumentation, Volume 11.es_ES
dc.source.bibliographicCitationLeo, W. R. (1987). Techniques for Nuclear and Particle Experiments. Berlín: Springer.es_ES
dc.source.bibliographicCitationMachado, A., & Segreto, E. (2016). ARAPUCA a new device for liquid argon scintillation light detection. Journal of Instrumentation,, Volume 11.es_ES
dc.source.bibliographicCitationMorris, G. (2005). The origin, ultrastructure, and microbiology of the sediment accumulating in liquid nitrogen storage vessels. Cryobiology, 231-238.es_ES
dc.source.bibliographicCitationParmegiani Lodovico, C. G. (2009). Ultra-violet sterilization of liquid nitrogen prior to vitrification. Human Reproduction, 2969.es_ES
dc.source.bibliographicCitationParmegiani, L., & et al. (2009). Sterilization of liquid nitrogen with ultraviolet irradiation for safe vitrification of human oocytes or embryos. Techniques and instrumentation, 1525-1528.es_ES
dc.source.bibliographicCitationParmegiani, L., Cognigni, G. E., & Filicori, M. (2011). Efficacy of ultraviolet sterilization of liquid nitrogen. Reproductive Medicine, 22.es_ES
dc.source.bibliographicCitationPessoa, G., Batistella, M., Mondino, C., & Costa da Rosa, D. (2014). Decontamination of naturally contaminated liquid nitrogen storage tanks. Revista Brasileira de Zootecnia., 5.es_ES
dc.source.bibliographicCitationRivero, G. J. (2012). CAPÍTULO I. GENERALIDADES DE LA CRIOPRESERVACIÓN. En G. J. Rivero, Modelado matemático e implementación práctica de sistema de vitrificación ultra-rápida mediante radiación láser (págs. 8-23). Sevilla: Universidad de Sevilla.es_ES
dc.source.bibliographicCitationSchalk, S., Adam, V., Arnold, E., & Brieden, K. (2005). UV-Lamps for Disinfection and Advanced Oxidation - Lamp Types,Technologies and Applications. IUVA News, 32-37.es_ES
dc.source.bibliographicCitationScotto, M. (2003). Molecular Motion and Raman Band Shapes in Liquid Nitrogen and Oxygen. The Journal of Chemical Physics, 5362.es_ES
dc.source.bibliographicCitationWhittington, D. (2015). Photon Detection System Designs for the Deep Underground Neutrino Experiment. arXiv.es_ES
dc.source.bibliographicCitationWischnewski , B. (Junio de 2007). peacesoftware. Berlín, Wagner-Str. 49, Alemania.es_ES
dc.source.bibliographicCitationYonezawa, F., & Ninomiya, T. (1982). Topological Disorder in Condensed Matter. Shimoda: Springer.es_ES
dc.description.degreenameDoctor(a) en Ciencia Aplicadaes_ES
dc.description.degreelevelDoctoradoes_ES
dc.publisher.facultyFacultad de Cienciases_ES
dc.description.funderConvocatoria Doctorados Nacionales, 757, 2016es_ES
dc.description.notesPresenciales_ES
dc.creator.orcidhttps://orcid.org/0000-0002-2646-620Xes_ES
dc.creator.cvlachttps://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0001343755es_ES
dc.creator.cedula53068081es_ES
dc.creator.cedula79728622es_ES
dc.creator.cedula10025092es_ES
dc.creator.cedula80417160es_ES
dc.publisher.campusBogotá - Circunvalar-
Aparece en las colecciones: Doctorado en Ciencia aplicada

Ficheros en este ítem:
Fichero Tamaño  
2020MaritzaDelgadoGonzalez.pdf.pdf7.12 MBVisualizar/Abrir
2020Autorizacióndeautores.pdf
  Restricted Access
818.82 kBVisualizar/Abrir  Request a copy


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons