dc.contributor.advisor | Gerena Mateus, Feissan Alonso | - |
dc.creator | Acosta Puerto, Oscar Eduardo | - |
dc.date.accessioned | 2021-03-03T14:52:09Z | - |
dc.date.available | 2021-03-03T14:52:09Z | - |
dc.date.created | 2020-06-06 | - |
dc.identifier.uri | http://repositorio.uan.edu.co/handle/123456789/2420 | - |
dc.description.abstract | The purpose of this comprehensive degree work is to design the instructions for testing overcurrent relays in electrical substations supported on a virtual platform with the protocols, procedures, and analysis on how to carry out the necessary tests on overcurrent relays and information from others. patio equipment in electrical substations, in accordance with International, National standards and recommendations given by the manufacturer. As a study and training for users of this instruction, information on overcurrent relays, transformers, switches, related to components that make them up, how they work and the different types that exist in the market is presented. The steps to follow during the process are specified, as well as how they should be carried out and what equipment is appropriate to carry out this type of tests. Likewise, the different tests that must be carried out according to the protocol of electrical substations are presented, based on the RETIE (Technical Regulation of electrical installations) regulations. This instruction is preceded by security regulations, equipment and tools used and finally the instructions are reflected in a virtual platform implemented with free software AUTOPLAY. With access to this platform, students of industrial electromechanical maintenance engineering and technology can carry out theoretical training to acquire the necessary skills to carry out this type of work in an electrical substation. KEY WORDS: AUTOPLAY, transformer, RETIE, relay, instructions. | es_ES |
dc.description.tableofcontents | El presente trabajo integral de grado tiene como finalidad diseñar el instructivo de pruebas a relés de sobrecorriente en subestaciones eléctricas soportado en una plataforma virtual con los protocolos, procedimientos y análisis sobre cómo se deben realizar las pruebas necesarias a relés de sobre corriente e información de otros equipos de patio en subestaciones eléctricas, de acuerdo con las normas Internacionales, Nacionales y recomendaciones dadas por el fabricante. Como estudio y entrenamiento para los usuarios de este instructivo se presenta información sobre relés de sobrecorriente, transformadores, interruptores, relacionada a componentes que los conforman, cómo funcionan y los diferentes tipos que existen en el mercado. Se especifican los pasos a seguir durante el proceso, además de cómo deben realizarse y cuáles son los equipos adecuados para realizar este tipo de pruebas. Así mismo se presentan las diferentes pruebas que deben ser realizadas de acuerdo al protocolo de subestaciones eléctricas, basado en la normativa de RETIE (Reglamento técnico de instalaciones eléctricas.). Este instructivo va precedido de normas de seguridad, equipos y herramientas utilizadas y finalmente el instructivo queda plasmando en una plataforma virtual implementada con el software libre AUTOPLAY. Con el acceso a esta plataforma los estudiantes de ingeniería y tecnología de mantenimiento electromecánico industrial pueden realizar un entrenamiento teórico para adquirir las competencias necesarias para realizar este tipo de trabajos en una subestación eléctrica. PALABRAS CLAVE: Autoplay, transformador, Retie, relé, instructivo. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad Antonio Nariño | es_ES |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.subject | Relés de sobrecorriente | es_ES |
dc.title | Instructivo para pruebas a relés de sobrecorriente en subestaciones eléctricas soportado en plataforma virtual | es_ES |
dc.publisher.program | Tecnología en Mantenimiento Electromecánico Industrial (Distancia) | es_ES |
dc.rights.accesRights | openAccess | es_ES |
dc.subject.keyword | overcurrent relays | es_ES |
dc.type.spa | Trabajo de grado (Pregrado y/o Especialización) | es_ES |
dc.type.hasVersion | info:eu-repo/semantics/acceptedVersion | es_ES |
dc.source.bibliographicCitation | Colombia. Instituto Colombiano de Normas Técnicas Y Certificación (ICONTEC). NORMA TECNICA COLOMBIA NTC 2131 (28 de julio de 1999). Apartado 14237 Bogotá D.C., 1999, 51 p. | es_ES |
dc.source.bibliographicCitation | Ingeniería T&D. Subgerencia de Distribución. Estructuras 34,5 kV. [En línea]. Norte de Santander. CENTRALES ELECTRICAS DEL NORTE DE SANTANDER S.A. E.S.P., 2017, 68 p. Disponible en http://www.cens.com.co/Portals/2/ESTRUCTURAS%2034.5%20KV%2016- 01-2017..pdf | es_ES |
dc.source.bibliographicCitation | NORMA DE DISTRIBUCION N.MA. 70.06/2 (8 de noviembre del 2004). Seccionadores de media tensión. [En línea], 2004, 15 p. Disponible en http://www.ute.com.uy/Empresa/lineas/distribucion/normalizacion/docs/NMA 70062.pdf. | es_ES |
dc.source.bibliographicCitation | Parametrización y caracterización de transformadores de corriente y de potencial de la red de distribución de la electrificadora de Santander/ Javier. | es_ES |
dc.source.bibliographicCitation | Pruebas eléctricas para puesta en marcha y mantenimiento de transformadores/ Megger/2010. | es_ES |
dc.source.bibliographicCitation | Reglamento Técnico de Instalaciones Eléctricas RETIE https://www.minminas.gov.co/documents/10180/1179442/Anexo+General+d el+RETIE+vigente+actualizado+a+2015-1.pdf/57874c58-e61e-4104-8b8cb64dbabedb13 | es_ES |
dc.source.bibliographicCitation | Seccionador de operación bajo carga tripolar de uso interior tipo GAV. [En línea]. Bogotá D.C. SOCOL S.A., 2012, 1 p. Disponible en http://socol.com.co/wpcontent/uploads/2015/06/2013-11-20-tarjeta-GAV-V.pdf | es_ES |
dc.source.bibliographicCitation | Soacha P., Leonardo. Trabajo de grado/ Universidad Industrial de Santander/ 2009. Pruebas eléctricas de diagnóstico a los transformadores de potencia/ Informe pasantía/Arturo José Lon/Universidad Simón Bolívar./2012. | es_ES |
dc.source.bibliographicCitation | Solis, I. E Luis Eduardo. Especificaciones técnicas y características técnicas garantizadas para seccionadores 34.5kv. Consecutivo del documento: LSF-CON-ASC297-EL-04. [En línea]. Villavicencio, Meta. ELECTRIFICADORA DEL META S.A E.S.P., 2009, 14 p. Disponible en http://www.emsaesp.com.co/new/contratacion/docs/docs529/LS-F-CON-ASC297-EL04%20SECCIONADORES%2034.5kV.pdf. | es_ES |
dc.description.degreename | Tecnólogo(a) en Mantenimiento Electromecánico Industrial | es_ES |
dc.description.degreelevel | Tecnológica | es_ES |
dc.publisher.faculty | Facultad de Ingeniería Mecánica, Electrónica y Biomédica | es_ES |
dc.description.notes | Distancia | es_ES |
dc.publisher.campus | Cúcuta | - |
Aparece en las colecciones: | Tecnología en mantenimiento electromecánico industrial |
Ficheros en este ítem:
Fichero | Tamaño | |
---|---|---|
2020_OscarAcosta | 2.8 MB | Visualizar/Abrir |
2020_OscarAcosta_Autorización Restricted Access | 614.61 kB | Visualizar/Abrir Request a copy |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons