Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.uan.edu.co/handle/123456789/2466
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Botina Trujillo, Kelyn Rosely | - |
dc.creator | Torres Vargas, Andres Leonardo | - |
dc.creator | Herrera Cardozo, Brayan Camilo | - |
dc.date.accessioned | 2021-03-03T16:25:20Z | - |
dc.date.available | 2021-03-03T16:25:20Z | - |
dc.date.created | 2020-06-06 | - |
dc.identifier.uri | http://repositorio.uan.edu.co/handle/123456789/2466 | - |
dc.description.abstract | In the area of occupational medicine, x-ray examinations are frequently performed to support the diagnosis of anthropometric shoulder imbalance, which is important for the detection of spine-related diseases such as scoliosis. However, continuous exposure to radiation dose is not recommended for the health of individuals. Therefore, alternatives have been proposed for the evaluation of this type of anthropometric imbalance, based on the application of advanced digital image processing techniques that require specialized computer resources and knowledge of advanced mathematics. Therefore, in the present integral work of degree a new non-invasive method is proposed in which a computational algorithm was developed that supports the medical diagnosis from the implementation of basic techniques of digital image processing based on the application of operations of linear algebra in photographs of the frontal plane of the human body to estimate the imbalance between shoulders with a low computational cost. The development of the computational algorithm was implemented in Matlab. The results of this work are compared with those obtained by means of a radiological examination in 5 patients who have the diagnosis of the X-ray examination and with the results provided by a health professional who applied the plumb test to establish the rise and fall of shoulders, that is, in this case there is no numerical value of the imbalance. | es_ES |
dc.description.sponsorship | Otro | es_ES |
dc.description.tableofcontents | En el área de medicina ocupacional se practican con frecuencia exámenes de rayos X para apoyar el diagnóstico del desbalance antropométrico entre hombros, el cual es importante para la detección de enfermedades relacionadas con la columna vertebral, como la escoliosis. Sin embargo, la continua exposición a dosis de radiación no es recomendable para la salud de las personas por lo que se han propuesto alternativas para la evaluación de este tipo de desniveles antropométricos, basadas en la aplicación de técnicas avanzadas de procesamiento digital de imágenes que requieren recursos computacionales especializados y conocimientos en matemática avanzada. Por consiguiente, en el presente trabajo integral de grado se propone un nuevo método no invasivo en el cual se desarrolló un algoritmo computacional que apoya el diagnóstico médico a partir de la implementación de técnicas básicas de procesamiento digital de imágenes basadas en la aplicación de operaciones de álgebra lineal en fotografías del plano frontal del cuerpo humano para estimar el desbalance entre hombros con un bajo costo computacional. El desarrollo del algoritmo computacional se implementó en Matlab. Los resultados de este trabajo son comparados con los obtenidos por medio de un examen radiológico en 5 pacientes que cuentan con el diagnóstico del examen de Rayos X y con los resultados suministrados por un profesional de salud que aplicó la prueba de plomada para establecer el ascenso y descenso de hombros, es decir, en este caso no se cuenta con un valor numérico del desbalance. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad Antonio Nariño | es_ES |
dc.rights | Atribución-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights | Atribución-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nd/3.0/us/ | * |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.subject | Desbalance antropométrico de hombros | es_ES |
dc.subject | Procesamiento digital de imágenes | es_ES |
dc.subject | Rayos X | es_ES |
dc.subject | Salud ocupacional | es_ES |
dc.title | Algoritmo de procesamiento digital de imágenes para la estimación del desbalance antropométrico entre hombros | es_ES |
dc.publisher.program | Ingeniería Electrónica | es_ES |
dc.rights.accesRights | openAccess | es_ES |
dc.subject.keyword | Anthropometric shoulder imbalance | es_ES |
dc.subject.keyword | Digital processing imaging | es_ES |
dc.subject.keyword | X-rays | es_ES |
dc.subject.keyword | Occupational health | es_ES |
dc.type.spa | Trabajo de grado (Pregrado y/o Especialización) | es_ES |
dc.type.hasVersion | info:eu-repo/semantics/acceptedVersion | es_ES |
dc.source.bibliographicCitation | Antenor Rafael de Oliceira Mazzuia, D. R. (2015). IPHONE APP USE TO COOB ANGLE IN ADOLESCENT IDIOPATICH SCOLIOSOS: DOES THIS APPLY? IEEE. | es_ES |
dc.source.bibliographicCitation | Descripción del producto MATLAB - MATLAB & Simulink—MathWorks América Latina. (s. f.). Recuperado 3 de septiembre de 2019, de https://la.mathworks.com/help/matlab/learn_matlab/product-description.html | es_ES |
dc.source.bibliographicCitation | energias, M. d. (06 de agosto de 2009). ministerio de minas y energias. Obtenido de minenergia.gov.co | es_ES |
dc.source.bibliographicCitation | García, T., Gutiérrez, A., & Fernández, D. (2019). Fiabilidad inter e intra-observador del software de evaluación postural (PAS / SAPO): una revisión sistemática. Revista andaluza de medicina del deporte. | es_ES |
dc.source.bibliographicCitation | Guerrero, & Guáqueta. (2016). Herramienta de apoyo diagnostico para deteccion de malformaciones en la columna. Bogotá. | es_ES |
dc.source.bibliographicCitation | Guillermo Navarro Oltra, J. R. (2008). Una introducción a la imagen digital y su tratamiento. | es_ES |
dc.source.bibliographicCitation | Jiménez, J. G. (2014). ESTUDIO COMPARATIVO DE DOSIS EQUIVALENTE DE RADIACIÓN RECIBIDA, UTILIZANDO CONE BEAM CON DIFERENTES CAMPOS DE VISIÓN (FIELD OF VIEW ). Santiago, Chile. | es_ES |
dc.source.bibliographicCitation | Kendall´s. (2007). Musculos pruebas funcionales postura y dolor. Marbán. | es_ES |
dc.source.bibliographicCitation | Marcos Joaquín Robles Ortiz, G. S. (2016). Detección temprana de la escoliosis idiopática del adolescente: una estrategia en controversia. Revista de la Facultad de Medicina (México). | es_ES |
dc.source.bibliographicCitation | Mathias M Adankon, N. C. (2013). Scoliosis follow-up using noninvasive trunk surface acquisition. IEEE. | es_ES |
dc.source.bibliographicCitation | Méndez, A. L. (2012). Radiación ionizante en tomografía computada: un tema de reflexión. Anales de Radiología México, 90-97. | es_ES |
dc.source.bibliographicCitation | MONOGRAPHS, I. (2000). EVALUATION OF CARCINOGENIC. Lyon, France: IARC Library. | es_ES |
dc.source.bibliographicCitation | Monsalve, C. Y. F., Corena, Z. M. G., & Samudio, M. P. O. (s. f.). Estudio de caso: Terapia manual en una paciente de 18 años con escoliosis juvenil idiopática. 13. | es_ES |
dc.source.bibliographicCitation | Lim, Jae S., Two-Dimensional Signal and Image Processing, Englewood Cliffs, NJ, Prentice Hall, 1990, pp. 469-476. | es_ES |
dc.source.bibliographicCitation | REAL ACADEMIA ESPAÑOLA: Diccionario de la lengua española, 23.ª ed., [Versión 23.3 en línea]. [2020]. | es_ES |
dc.source.bibliographicCitation | Paez, F. (s.f.). Physical Tech. Obtenido de http://physicaltech.com/ | es_ES |
dc.source.bibliographicCitation | Puneet, P., & Garg, N. (2013). Binarization Techniques used for Grey Scale Images. International Journal of Computer Applications, 71(1), 8-11. https://doi.org/10.5120/12320-8533 | es_ES |
dc.source.bibliographicCitation | Tássia Silveira Furlanetto, J. A. (2016). La fotogrametría como herramienta para la evaluación postural de la columna vertebral: una revisión sistemática. world journal of orthopedics. | es_ES |
dc.source.bibliographicCitation | Tirado LR, L. R., González FD, F. D., & Sir FJ, F. J. (2015). Uso controlado de los rayos X en la práctica odontológica. Ciencias de la Salud, 13(1), 99-112. https://doi.org/10.12804/revsalud13.01.2015.08 | es_ES |
dc.source.bibliographicCitation | Venegas, A. L. (22 de febrero de 2019). Los celulares de gama media son los que más compran a cuotas los colombianos. La republica. | es_ES |
dc.description.degreename | Ingeniero(a) Electrónico(a) | es_ES |
dc.description.degreelevel | Pregrado | es_ES |
dc.publisher.faculty | Facultad de Ingeniería Mecánica, Electrónica y Biomédica | es_ES |
dc.description.funder | $6.680.000 (de acuerdo a lo reportado en el anteproyecto): $1.000.000 (Propios) $2.500.000 (IPS) $3.180.000 (UAN) | es_ES |
dc.description.notes | Presencial | es_ES |
dc.publisher.campus | Neiva Buganviles | - |
Aparece en las colecciones: | Ingeniería electrónica |
Ficheros en este ítem:
Fichero | Tamaño | |
---|---|---|
2020_AndresLeonardoTorresVargas | 1.81 MB | Visualizar/Abrir |
2020_AndresLeonardoTorresVargas_Autorización Restricted Access | 465.27 kB | Visualizar/Abrir Request a copy |
2020_BrayanCamiloHerreraCardozo_Autorización Restricted Access | 460.49 kB | Visualizar/Abrir Request a copy |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons