dc.description.abstract | The following project aims to characterize electrical energy in the manufacture of Clinker l2, a cement process from the eastern Sogamoso headquarters, which is divided into four areas: crude milling, homogenization, clinkerization, and coal grinding present on line 2 During the normal operation of this process, there were problems that generated stoppages in these areas, it was identified that these were generated by trips of motor protections, trip of totalizers and damage to electric motors, heating of conductors in the aforementioned areas. It was proposed to analyze the energy quality by updating the version of meters, software and equipment conditions present in the mentioned areas, giving way to criteria in reactive power and power factor; to reach a continuous improvement in the values of reliability, monitoring and detection of harmonics. The management in the effective selection of the meters was determined thanks to their versatility. This led us to obtain a greater analysis capacity in the electrical variables, therefore, the software has a dynamic compatibility in its interface, making it very friendly and easy. in its configuration; On the other hand, the data obtained in the equipment survey gave us an operation parameterization, as a consequence, more detailed analyzes of the performance of capacitor banks were achieved to confront the final results with the process that was being carried out. | es_ES |
dc.description.sponsorship | Otro | es_ES |
dc.description.tableofcontents | El siguiente proyecto tiene como finalidad la caracterización energética eléctrica en la fabricación de Clinker l2, un proceso de cementos del oriente sede Sogamoso, este se encuentra dividido en cuatro áreas, molienda de crudo, homogenización, clinkerización , molienda de carbón presentes en la línea 2, durante la operación normal de este proceso se presentaban problemas que generaban paros en estas áreas, se identificó que estos eran generados por disparos de protecciones de motores, disparo de totalizadores y daños en motores eléctricos, calentamiento de conductores en las áreas antes mencionadas. Se propuso analizar la calidad de energía actualizando la versión de medidores, software y condiciones de los equipos presentes en las áreas mencionadas, dando paso a criterios en la potencia reactiva y factor de potencia; para llegar a una mejora continua en los valores de confiablidad, seguimiento y detección de armónicos. Se determinó la gestión en la selección eficaz de los medidores gracias a la versatilidad de los mismos este nos llevó a obtener una mayor capacidad de análisis en las variables eléctricas, por consiguiente, el software tiene una compatibilidad dinámica en su interfaz haciéndola muy amigable y fácil en su configuración; por otra parte, los datos obtenidos en el levantamiento de los equipos nos dieron una parametrización de operación, a consecuencia se logró unos análisis más detallados en el desempeño de bancos de condensadores para confrontar los resultados finales con el proceso que se venía desempeñando. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad Antonio Nariño | es_ES |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.subject | Energía Activa | es_ES |
dc.subject | Energía Reactiva | es_ES |
dc.subject | Factor de potencia | es_ES |
dc.subject | Armónicos | es_ES |
dc.subject | Eficiencia Energética | es_ES |
dc.subject | Calidad de Energía | es_ES |
dc.title | Caracterización energética y plan de mejoramiento en el sistema eléctrico del clinker l2 de la planta cementos del oriente sede Sogamoso | es_ES |
dc.publisher.program | Ingeniería Electrónica | es_ES |
dc.rights.accesRights | openAccess | es_ES |
dc.subject.keyword | Active energy | es_ES |
dc.subject.keyword | Reactive energy | es_ES |
dc.subject.keyword | Power factor | es_ES |
dc.subject.keyword | Harmonic | es_ES |
dc.subject.keyword | Energy efficiency | es_ES |
dc.subject.keyword | Energy quality | es_ES |
dc.type.spa | Trabajo de grado (Pregrado y/o Especialización) | es_ES |
dc.type.hasVersion | info:eu-repo/semantics/acceptedVersion | es_ES |
dc.source.bibliographicCitation | M. Gerin, “Guía de diseño de instalaciones eléctricas Según normas internacionales IEC,”, 2nd ed. vol. 3, J. Peters, Ed. New York: Schneider Electric, 2013. | es_ES |
dc.source.bibliographicCitation | T. M. Blooming y D. J. Carnovale, “Application of IEEE STD 519-1992 Harmonic Limits”, en Conference Record of 2006 Annual Pulp and Paper Industry Technical Conference, jun. 2006, pp. 1–9, doi: 10.1109/PAPCON.2006.1673767. | es_ES |
dc.source.bibliographicCitation | A. R. Oliva y J. C. Balda, “A PV dispersed generator: a power quality analysis within the IEEE 519”, IEEE Trans. Power Deliv., vol. 18, núm. 2, pp. 525–530, abr. 2003, doi: 10.1109/TPWRD.2003.809685. | es_ES |
dc.source.bibliographicCitation | J. Correa Soto, A. E. Borroto Nordelo, M. Alpha Bah, R. González Álvarez, M. Curbelo Martínez, y A. M. Díaz Rodríguez, “Diseño y aplicación de un procedimiento para la planificación energética según la NC-ISO 50001:2011”, Ing. Energética, vol. 35, núm. 1, pp. 38–47, abr. 2014. | es_ES |
dc.source.bibliographicCitation | R. D. P. Castrillon, “MEJORAMIENTO DE LA EFICIENCIA ENERGÉTICA EN LA INDUSTRIA DEL CEMENTO POR PROCESO HÚMEDO A TRAVÉS DE LA IMPLEMENTACIÓN DEL SISTEMA DE GESTIÓN INTEGRAL DE LA ENERGÍA”, p. 10. | es_ES |
dc.source.bibliographicCitation | M. A. Echeverría Cruz y O. A. López Mena, “Caracterización energética de la cascarilla de arroz para su aplicación en la generación de energía termoeléctrica”, may 2010, Consultado: jul. 06, 2020. [En línea]. Disponible en: http://bibdigital.epn.edu.ec/handle/15000/2058. | es_ES |
dc.source.bibliographicCitation | “1080224379.pdf”. Consultado: jul. 06, 2020. [En línea]. Disponible en: http://eprints.uanl.mx/3305/1/1080224379.pdf. | es_ES |
dc.source.bibliographicCitation | “Corrección activa del factor de potencia en cargas no lineales | Tecnura”. https://revistas.udistrital.edu.co/index.php/Tecnura/article/view/6184 (consultado jul. 06, 2020). | es_ES |
dc.source.bibliographicCitation | P. Suárez y J. Farith, “Control de filtros activos de potencia para la mitigación de armónicos y mejora del factor de potencia en sistemas desequilibrados”, 2007, Consultado: jul. 06, 2020. [En línea]. Disponible en: https://e-archivo.uc3m.es/handle/10016/2384. | es_ES |
dc.description.degreename | Ingeniero(a) Electrónico(a) | es_ES |
dc.description.degreelevel | Pregrado | es_ES |
dc.publisher.faculty | Facultad de Ingeniería Mecánica, Electrónica y Biomédica | es_ES |
dc.description.funder | $32.783.883 (de acuerdo a lo reportado en el anteproyecto): $3.270.000 (Propios) $30.198.883 (Empresa) | es_ES |
dc.description.notes | Presencial | es_ES |
dc.publisher.campus | Tunja | - |
Aparece en las colecciones: | Ingeniería electrónica |
Ficheros en este ítem:
Fichero | Tamaño | |
---|---|---|
2020CarlosFernandoAlfonsoBallesteros.pdf | 10.08 MB | Visualizar/Abrir |
2020AutorizacióndeAutores.pdf Restricted Access | 725.17 kB | Visualizar/Abrir Request a copy |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons