Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.uan.edu.co/handle/123456789/2734
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorAguilar, Exiomara-
dc.contributor.advisorBautista, Cesar Augusto-
dc.creatorMantilla Nieto, Leonardo-
dc.creatorRomero Redondo, Davier David-
dc.date.accessioned2021-03-06T15:27:55Z-
dc.date.available2021-03-06T15:27:55Z-
dc.date.created2020-06-04-
dc.identifier.urihttp://repositorio.uan.edu.co/handle/123456789/2734-
dc.description.abstractObjectives: To evaluate the fracture resistance of thermocuring acrylic resins used for the production of prosthetic bases for total prostheses, using metal inserts. Materials and methods: Thirty (30) samples, in heat-curing PMMA, Veracryl referenced VR1 by New Stetic, distributed in three (3) groups of 10 each, identified SR (no reinforcement), RM (mesh reinforcement), RR (grid reinforcement). They were subjected to vertical force on a deflection bench, at a constant force in Kgf, until a fracture was reached. The present study is qualitative in vitro. Results : When comparing the acrylic samples for thermocuring prosthetic base distributed in three groups of the samples in without metallic insert (10), mesh insert (10) and insert with grid (10) and subjecting them to load tests in a deflection bench, it was determined that there is no significant statistical difference because they are out of the range p = 0. 05, in terms of flexural strength, but there were observational differences in structural conservation by the samples with insert (mesh and grid) from those that did not contain them and which were dispersed. Conclusions: It can be concluded, based on the results of the applied statistical tool that the fracture resistance does not present significant differences in the sample groups of the analyzed tests, determining that the samples that contained inserts (mesh and/or grid), compared with those that did not contain any type of insert, the fracture resistance for each one of the samples are not very different, existing slightly superior values in the group without reinforcement.es_ES
dc.description.tableofcontentsObjetivos: Evaluar la resistencia a la fractura de las resinas acrílicas de termocurado utilizadas para la elaboración de las bases protésicas para prótesis totales, utilizando insertos metálicos. Materiales y métodos: Se realizaron 30 muestras, en PMMA de termocurado,Veracryl referencian VR1 de New Stetic, distribuidas en tres (3) grupos de 10 cada una, identificadas SR (sin refuerzo), RM (refuerzo malla), RR(refuerzo rejilla). Se sometieron a fuerza vertical en un banco de deflexión, a una fuerza constante en Kgf, hasta alcanzar una fractura. El presente estudio es cualitativo in vitro. Resultados : Al comparar las muestras de acrílico para base protésicas de termocurado distribuidos en tres grupo de las muestras en sin inserto metálico (10), inserto tipo malla(10) e inserto con rejilla (10) y someterlas a pruebas de carga en un banco de deflexión, se determinó que no existe diferencia estadística significativa por estar fuera del rango p = 0.05, en cuanto a la resistencia flexural, pero si diferencias observacionales de conservación estructural por parte de las muestras con inserto (malla y rejilla) de aquellas que no los contenían y las cuales se dispersaron. Conclusiones: Se puede concluir, basados en los resultados de la herramienta estadística aplicada que la resistencia de la fractura no presenta diferencias significativa en los grupos muestra de los ensayos analizados, determinando que las muestras que contenían insertos (malla y/o rejilla), comparadas con aquellas que no contenían ningún tipo de inserto, la resistencia a la fractura para cada una de las muestras no son muy diferentes, existiendo valores ligeramente superiores en el grupo sin refuerzo.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América*
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.subjectPrótesises_ES
dc.subjectBase acrílicaes_ES
dc.subjectInsertoes_ES
dc.subjectDeflexiónes_ES
dc.titleEvaluación de la resistencia a la fractura de bases protésicas en prótesis totales utilizando insertos metálicoses_ES
dc.publisher.programOdontologíaes_ES
dc.rights.accesRightsopenAccesses_ES
dc.subject.keywordProsthesises_ES
dc.subject.keywordAcrylic basees_ES
dc.subject.keywordInsertes_ES
dc.subject.keywordDeflectiones_ES
dc.type.spaTrabajo de grado (Pregrado y/o Especialización)es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.source.bibliographicCitationAcosta, H., Bernal, G., Fernandez, E., Mardones, F., Monardes, H., Roman, J., & Segovia, J. (2013). Modificaciones de diseño protésico para mejorar estética en prótesis parcial removible metálica. Avances en odontoestomatologia, 175-183.es_ES
dc.source.bibliographicCitationAgudelo, A., Gómez, J., Gómez, M., Paez, M., Silva, M., & Z. F. (2017). Salud bucal y factores relacionados en pacientes portadores de prótesis bimaxilar en una institución docenciaservicio de Medellín, Colombia. Rev Nac Odontol, 65-77.es_ES
dc.source.bibliographicCitationAngeles, F., Alfaro, P., Nuñez, J., Osorio, M., & Romero, G. (2012). Fuerza de mordida: su importancia en la masticación,su medición y sus condicionantes clinicos. Parte I. Revista ADM, 53-57.es_ES
dc.source.bibliographicCitationAnusavice, K. (2004). Phillips ciencia de los materiales dentales (undecima ed.). Genova, España: elsevier.es_ES
dc.source.bibliographicCitationAtala, J., Cabral, R., Ibañez, C., Ocampo, M., & Lagnarini, L. (2017). Comparación de la resistencia de resinas actuales para próteis completas procesadas en tiempos cortos y en tiempos convencionales. Revista Facultad de odontologia universeidad nacional de cordoba, 27(2), 36-42.es_ES
dc.source.bibliographicCitationBagby, M., & Gladwin, M. (2001). Aspectos clinicos de los materiales en odontologia. Mexico: El manual moderno.es_ES
dc.source.bibliographicCitationCabezas, C. (mayo de 2017). Influencia de los cambios termicos en la resistencia flexural de los acrilicos de termocurado para la base de dentaduras co i sin insertos metalicos: Estudio in vitro (tesis de pregrado).es_ES
dc.source.bibliographicCitationCardenas, C., Florez, J., & Orejuela, M. (2017). Indice de la corrosion en resistencia a la flexion del acero AISI-SAE1020 (tesis pregrado). universidad antonio nariño, 1-160.es_ES
dc.source.bibliographicCitationCastillo, R., Herrera, S., Jaramillo, A., Mejia, C., & Rey, P. (2011). Comparacion de las propiedades tensionales de resinas acrilicas de termocuradopara elaboracion de bases protesicas. Revista estomatologica, 20-25.es_ES
dc.source.bibliographicCitationCho, L., Huh, Y., Im, S., & Park, C. (2017). Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading. The Journal of Advanced Prosthodontics, 22-30. doi:https://doi.org/10.4047/jap.2017.9.1.22es_ES
dc.source.bibliographicCitationColombia. Minsiterio de Salud y Proteccion Social. (2014). IV estudio nacional de salud bucal, ENSAB. Bogota.es_ES
dc.source.bibliographicCitationCortez, L., Garzon, Z., & Zarate, L. (2017). estudio comparativo in vitro del efecto de almacenamiento nocturno de la rugosidad superficial de las bases protesicas elaborada con resina acrilica de termopolimerizacion (tesis postgrado). universidad santo tomas, 65.es_ES
dc.source.bibliographicCitationDeBoer, J., Vemilyea, S., & Brady, R. (1984). El efecto de la orientacion de la figra de carbono sobre la resistencia a la fatiga y las propiedades de la flexion de dos resinas para dentaduras postizas. The Journal of prosthetic dentistry , 119-121.es_ES
dc.source.bibliographicCitationEckert, S., Hobkirk, J., Jacob, R., & Zarb, G. (2013). Prosthodontic treatment for edentulous patients (13 ed.). St. Louis. Missouri: Elsevier - Mosby.es_ES
dc.source.bibliographicCitationEl-Sheikh, A., & Al-Zahrani, S. (2006). Causes of denture fracture : A survey. Saudi Dental Journal, 149-154.es_ES
dc.source.bibliographicCitationFelton, D., Cooper, L., Dugum, I., Minsley, G., Haug, S., Meredith, P., . . . Avery, C. (2011). Evidence-based guidelines for the care and maintenance of complete dentures. (A. c. prosthodontics, Ed.) Journal of prosthodontics, S1-S11.es_ES
dc.source.bibliographicCitationGonzález, Z. P., & Tasende, A. (2012). Registro de pacientes portadores de prótesis en unidades de salud bucodental en atencion primaria. Cadernos de atención primaria, 18, 26-32.es_ES
dc.source.bibliographicCitationGuerrero I, J., Osorio N, A., & Santos E, A. (2014). Infl uencia de los cambios térmicos en la defl exión transversa de acrilicos para la base de dentaduras con y sin insertos metalicos . Revista odontologica mexicana, 170-174.es_ES
dc.source.bibliographicCitationHaralur, S., Khare, S., Murthy, H., Roopa, .., Sachdeva, H., & Shaik, S. (2015). Effect of reinforcement using stainless steel mesh, glass fibers, and polyethylene on the impact strength of heat cure denture base resin - An In Vitro Study. Journal of International Oral Health, 71-79.es_ES
dc.source.bibliographicCitationKeopgh, T., & Mallat, E. (1995). Protesis parcial removible, Clinica y laboratorio. Madrid, España: Mosby/doyma libros.es_ES
dc.source.bibliographicCitationKhalid, H. (2011). Causes and types or complete denture fracture. Zanco Journal of medical sciences, 15(3), 36-40.es_ES
dc.source.bibliographicCitationLarrea, I. (2018). Resistencia flexural del acrilico de termocurado reforzado con nanoplacas de grafeno ( tesis pregado). Universidad central de ecuador, 104.es_ES
dc.source.bibliographicCitationMinisterio de Salud y proteccion social. (1993). Resolucion numero 8430 de 1993. Bogota: imprenta nacional.es_ES
dc.source.bibliographicCitationMisch, C. (2007). Protesis dental sobre implantes. Madrid: Elsevier.es_ES
dc.source.bibliographicCitationNew Stetic. (2009). Ficha tecnica Resina acrilica termopolimerizable VERACRIL®, OPTI-CRYL® DPFTPT-025. Guarne, Colombia. Obtenido de https://newstetic.s3-us-west-2.amazonaws.com/newstetic/document_products/pdfs/127/ft_acrilico_termo.pdf?1582573456es_ES
dc.source.bibliographicCitationPerez, M. (2001). Variación en el diseño de la prótesis parcial por diferentes laboratorios dentales. Revista ADM, 74-79.es_ES
dc.source.bibliographicCitationAcosta, H., Bernal, G., Fernandez, E., Mardones, F., Monardes, H., Roman, J., & Segovia, J. (2013). Modificaciones de diseño protésico para mejorar estética en prótesis parcial removible metálica. Avances en odontoestomatologia, 175-183. Agudelo, A., Gómez, J., Gómez, M., Paez, M., Silva, M., & Z. F. (2017). Salud bucal y factores relacionados en pacientes portadores de prótesis bimaxilar en una institución docenciaservicio de Medellín, Colombia. Rev Nac Odontol, 65-77. Angeles, F., Alfaro, P., Nuñez, J., Osorio, M., & Romero, G. (2012). Fuerza de mordida: su importancia en la masticación,su medición y sus condicionantes clinicos. Parte I. Revista ADM, 53-57. Anusavice, K. (2004). Phillips ciencia de los materiales dentales (undecima ed.). Genova, España: elsevier. Atala, J., Cabral, R., Ibañez, C., Ocampo, M., & Lagnarini, L. (2017). Comparación de la resistencia de resinas actuales para próteis completas procesadas en tiempos cortos y en tiempos convencionales. Revista Facultad de odontologia universeidad nacional de cordoba, 27(2), 36-42. Bagby, M., & Gladwin, M. (2001). Aspectos clinicos de los materiales en odontologia. Mexico: El manual moderno. Cabezas, C. (mayo de 2017). Influencia de los cambios termicos en la resistencia flexural de los acrilicos de termocurado para la base de dentaduras co i sin insertos metalicos: Estudio in vitro (tesis de pregrado). Cardenas, C., Florez, J., & Orejuela, M. (2017). Indice de la corrosion en resistencia a la flexion del acero AISI-SAE1020 (tesis pregrado). universidad antonio nariño, 1-160. Castillo, R., Herrera, S., Jaramillo, A., Mejia, C., & Rey, P. (2011). Comparacion de las propiedades tensionales de resinas acrilicas de termocuradopara elaboracion de bases protesicas. Revista estomatologica, 20-25. Cho, L., Huh, Y., Im, S., & Park, C. (2017). Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading. The Journal of Advanced Prosthodontics, 22-30. doi:https://doi.org/10.4047/jap.2017.9.1.22 Colombia. Minsiterio de Salud y Proteccion Social. (2014). IV estudio nacional de salud bucal, ENSAB. Bogota. Cortez, L., Garzon, Z., & Zarate, L. (2017). estudio comparativo in vitro del efecto de almacenamiento nocturno de la rugosidad superficial de las bases protesicas elaborada con resina acrilica de termopolimerizacion (tesis postgrado). universidad santo tomas, 65. DeBoer, J., Vemilyea, S., & Brady, R. (1984). El efecto de la orientacion de la figra de carbono sobre la resistencia a la fatiga y las propiedades de la flexion de dos resinas para dentaduras postizas. The Journal of prosthetic dentistry , 119-121. Eckert, S., Hobkirk, J., Jacob, R., & Zarb, G. (2013). Prosthodontic treatment for edentulous patients (13 ed.). St. Louis. Missouri: Elsevier - Mosby. El-Sheikh, A., & Al-Zahrani, S. (2006). Causes of denture fracture : A survey. Saudi Dental Journal, 149-154. Felton, D., Cooper, L., Dugum, I., Minsley, G., Haug, S., Meredith, P., . . . Avery, C. (2011). Evidence-based guidelines for the care and maintenance of complete dentures. (A. c. prosthodontics, Ed.) Journal of prosthodontics, S1-S11. González, Z. P., & Tasende, A. (2012). Registro de pacientes portadores de prótesis en unidades de salud bucodental en atencion primaria. Cadernos de atención primaria, 18, 26-32. Guerrero I, J., Osorio N, A., & Santos E, A. (2014). Infl uencia de los cambios térmicos en la defl exión transversa de acrilicos para la base de dentaduras con y sin insertos metalicos . Revista odontologica mexicana, 170-174. Guzmán, H. (2013). Biomateriales odontologicos de uso clinico (5 ed.). Bogota: Ecoe editores. Haralur, S., Khare, S., Murthy, H., Roopa, .., Sachdeva, H., & Shaik, S. (2015). Effect of reinforcement using stainless steel mesh, glass fibers, and polyethylene on the impact strength of heat cure denture base resin - An In Vitro Study. Journal of International Oral Health, 71-79. Keopgh, T., & Mallat, E. (1995). Protesis parcial removible, Clinica y laboratorio. Madrid, España: Mosby/doyma libros. Khalid, H. (2011). Causes and types or complete denture fracture. Zanco Journal of medical sciences, 15(3), 36-40. Larrea, I. (2018). Resistencia flexural del acrilico de termocurado reforzado con nanoplacas de grafeno ( tesis pregado). Universidad central de ecuador, 104. Ministerio de Salud y proteccion social. (1993). Resolucion numero 8430 de 1993. Bogota: imprenta nacional. Misch, C. (2007). Protesis dental sobre implantes. Madrid: Elsevier. New Stetic. (2009). Ficha tecnica Resina acrilica termopolimerizable VERACRIL®, OPTI-CRYL® DPFTPT-025. Guarne, Colombia. Obtenido de https://newstetic.s3-us-west-2.amazonaws.com/newstetic/document_products/pdfs/127/ft_acrilico_termo.pdf?1582573456 Perez, M. (2001). Variación en el diseño de la prótesis parcial por diferentes laboratorios dentales. Revista ADM, 74-79. Power, J., & Sakaguchi, R. (2012). Craig's Restorative dental materials. Philadelphia, estados unidos: elsevier/mosby.es_ES
dc.description.degreenameOdontólogo(a)es_ES
dc.description.degreelevelPregradoes_ES
dc.publisher.facultyFacultad de Odontologíaes_ES
dc.description.notesPresenciales_ES
dc.publisher.campusBucaramanga-
Aparece en las colecciones: Odontología

Ficheros en este ítem:
Fichero Tamaño  
2020_LeonardoMantillaNieto1.18 MBVisualizar/Abrir
2020_LeonardoMantillaNieto_Autorización
  Restricted Access
264.73 kBVisualizar/Abrir  Request a copy


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons