dc.description.abstractThe present study focused on carrying out a characterization of energy consumption in the Chrisban Hotel Boutique in order to propose alternatives for the adoption of strategies focused on obtaining greater energy efficiency, determining criteria and requirements applicable to the hotel based on the ISO 50001 standard. Therefore, an energy management system was designed under the continuous improvement cycle PHVA (PlanDo-Verify-Act) together with three proposals for the reduction of electricity consumption, mainly in the changes of technologies to LED lighting, the use of inverter technology in air conditioning equipment, in addition to an alternative in the use of photovoltaic solar energy.es_ES
dc.description.tableofcontentsEl presente estudio se centró en realizar una caracterización del consumo energético en el Chrisban Hotel Boutique con el fin de proponer alternativas para la adopción de estrategias enfocadas a obtener una mayor eficiencia energética, determinando criterios y requerimientos aplicables al hotel con base a la norma ISO 50001 por lo que se diseñó un sistema de gestión de la energía bajo el ciclo de mejora continua PHVA (Planificar-HacerVerificar-Actuar) junto con tres propuestas para la reducción del consumo eléctrico, principalmente en los cambios de tecnologías a iluminación LED, el uso de tecnología inverter en equipos de aire acondicionado, Además de una alternativa en el uso de energía solar fotovoltaica.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América*
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.subjectConsumo eléctricoes_ES
dc.subjectEficiencia energéticaes_ES
dc.subjectISO 50001es_ES
dc.titlePropuesta de un plan de eficiencia energética en el hotel Chrisban Hotel Boutiquees_ES
dc.typeTesis - Trabajo de grado - Monografia - Pregradoes_ES
dc.publisher.programIngeniería Electromecánicaes_ES
dc.rights.accesRightsopenAccesses_ES
dc.subject.keywordElectricity consumptiones_ES
dc.subject.keywordEnergy efficiencyes_ES
dc.subject.keywordISO 50001.es_ES
dc.type.spaTrabajo de grado (Pregrado y/o Especialización)es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.source.bibliographicCitationAEDHE y Fundación MAPFRE. (2011). Guía Práctica para la implantación de sistemas de gestión energética. http://www.comunidadism.es/wpcontent/uploads/downloads/2011/05/guia-pr%C3%A1ctica-paraimplantaci%C3%B3n-de-sistemas-de-EE.pdf.es_ES
dc.source.bibliographicCitationAgencia Chilena de Eficiencia Energética, AChEE. (2017). Beneficios de los Sistemas de Gestión de Energía basados en ISO 50001 y casos de éxito. GuiaISO 50001, https://guiaiso50001.cl/guia/wpcontent/uploads/2017/05/Casos_exito_correccion9.pdf.es_ES
dc.source.bibliographicCitationAlburquerque, F. (1995). Competitividad internacional, estrategia empresarial y papel de las regiones. Revista EURE 21(63), 41-56. http://mail.eure.cl/index.php/eure/article/view/1138/240 .es_ES
dc.source.bibliographicCitationArturo, K. (2019). ¿Qué es el retorno de la inversión (ROI)? Crece Negocios, https://www.crecenegocios.com/roi/.es_ES
dc.source.bibliographicCitationBanco Mundial. (2019). Medio ambiente. Entendiendo a la pobreza, https://www.bancomundial.org/es/topic/environment/overview#1.es_ES
dc.source.bibliographicCitationBarrera, J. (2017). Estudio diagnóstico energético del iberostar grand hotel trinidad . [tesis de pregrado, Universidad Central “Marta Abreu” de las Villas], La Habana, Cuba.es_ES
dc.source.bibliographicCitationBellver, E. (2020). Diferencias entre aire acondicionado inverter vs no inverter. https://www.periodistadigital.com/magazine/escaparate/20200726/diferenciasaire-acondicionado-inverter-vs-inverter-noticia-689403837685/.es_ES
dc.source.bibliographicCitationBerrios, M. (2019). ISO 50001. La solución ideal para el ahorro energético. Cinde.es, http://cinde.es/blog/iso-50001-la-solucion-ideal-para-el-ahorro-energetico/.es_ES
dc.source.bibliographicCitationBlog de Lucera. (s.f.). ¿Como Elegir Un Aire Acondicionado? Obtenido de Recuperado el 10 abril 2020 de https://lucera.es/blog/como-elegir-aire-acondicionadoes_ES
dc.source.bibliographicCitationBorroto, A. (2009). Tecnologia de Gestión Total Eficiente de la Energía. Cienfuegos, Cuba: Editorial Universo Sur.es_ES
dc.description.degreenameIngeniero(a) Electromecánico(a)es_ES
dc.description.degreelevelPregradoes_ES
dc.publisher.facultyFacultad de Ingeniería Mecánica, Electrónica y Biomédicaes_ES
dc.audienceEspecializadaes_ES
dc.description.notesDistanciaes_ES
dc.creator.cedula21131615108es_ES
dc.publisher.campusBugaes_ES
dc.description.degreetypeMonografíaes_ES
Aparece en las colecciones: Ingeniería electromecánica

Ficheros en este ítem:
Fichero Tamaño  
2021_JohnJanerBarrera.pdf2 MBVisualizar/Abrir
2021_JohnJanerBarrera_Autorización.pdf
  Restricted Access
295.22 kBVisualizar/Abrir  Request a copy
2021_JohnJanerBarrera_Acta.pdf
  Restricted Access
228.74 kBVisualizar/Abrir  Request a copy


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons