dc.description.abstractPollution by high levels of particulate matter is a problem in indoor enclosures and other enclosed spaces, since in many cases the level of concentration present in these sites is unknown because measurements are not performed periodically and the methods used in these are not entirely effective and do not meet their needs when mitigating this problem, for this reason it was implemented a Control of particulate matter PM2. 5 and PM10 in enclosed areas of the Antonio Nariño University in Villavicencio, by means of a portable HEPA filter, which allows controlling the level of particulate matter in enclosed spaces; for this it was necessary to recognize and characterize the areas that were the object of the study, which had to be transited and frequented in order to reflect a real situation, in addition, the sampling method to be used was established, as well as the electronic elements used to make the measurements, these measurements were made during 15 days to be able to evidence the reality of each area in the different variables evaluated; Finally, the elements and additional tools that were used for the elaboration of the filter were described. This filter was installed in one of the previously selected enclosures, in order to demonstrate the changes in the amount of particulate matter that occurred there.es_ES
dc.description.tableofcontentsLa contaminación por altos niveles de material particulado es un problema en recintos interiores y otros espacios cerrados, ya que en muchos casos se desconoce el nivel de concentración presente en estos sitios debido a que no se realizan mediciones de manera periódica y los métodos usados en estas no son del todo eficaces y no se ajustan a sus necesidades a la hora de mitigar este problema, por esta razón se implementó un Control de material particulado PM2.5 y PM10 en recintos cerrados de la Universidad Antonio Nariño en Villavicencio, mediante un filtro portátil HEPA, que permita controlar el nivel de material particulado en los espacios cerrados; para esto fue necesario realizar el reconocimiento y caracterización de los recintos que fueron objeto de estudio, los cuales tuvieron que ser transitados y concurridos para poder reflejar una situación real, además, se estableció el método de muestreo a utilizar, así como los elementos electrónicos usados para realizar las mediciones, dichas mediciones fueron efectuadas durante 15 días para poder evidenciar la realidad de cada recinto en las diferentes variables evaluadas; por último, se describieron los elementos y las herramientas adicionales que fueron usadas para la elaboración del filtro, dicho filtro fue instalado en uno de los recintos previamente seleccionados, con el fin de evidenciar los cambios en la cantidad de material particulado que allí se presentaron.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.subjectMaterial particuladoes_ES
dc.subjectCalidad del airees_ES
dc.subjectFiltro portátiles_ES
dc.subjectMétodo de muestreoes_ES
dc.subjectRecintos cerradoses_ES
dc.titleControl de material particulado en espacios cerrados (laboratorio, preclínica y oficinas) a través de la utilización de un filtro portátil.es_ES
dc.typeTesis - Trabajo de grado - Monografia - Pregradoes_ES
dc.publisher.programIngeniería Industriales_ES
dc.rights.accesRightsopenAccesses_ES
dc.subject.keywordParticulate matteres_ES
dc.subject.keywordAir qualityes_ES
dc.subject.keywordPortable filteres_ES
dc.subject.keywordSampling methodes_ES
dc.subject.keywordClosed enclosureses_ES
dc.type.spaTrabajo de grado (Pregrado y/o Especialización)es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.source.bibliographicCitationAgencia de Protección Ambiental en Español. (22 de Mayo de 2018). EPA en Español. Obtenido de https://espanol.epa.gov/espanol/conceptos-basicos-sobre-el-materialparticulado-pm-por-sus-siglas-en-ingleses_ES
dc.source.bibliographicCitationAlarcón V, L. (2017). Spatial study of the health risk index by inhalation of PM2.5 during the dry season in the metropolitan area of the Toluca Valley. IAEA, 58.es_ES
dc.source.bibliographicCitationAmerican Psychological Association. (2010). Manual de Publicaciones de la American Psychological Association (6 ed.). (M. G. Frías, Trad.) México, México: El Manual Moderno.es_ES
dc.source.bibliographicCitationArciniégas Suárez, C. A. (2012). DIAGNÓSTICO Y CONTROL DE MATERIAL PARTICULADO: PARTÍCULAS SUSPENDIDAS TOTALES Y FRACCIÓN RESPIRABLE PM10*. Luna Azul. Obtenido de http://www.scielo.org.co/pdf/luaz/n34/n34a12.pdfes_ES
dc.source.bibliographicCitationArrieta Fuentes, A. J. (2016). Dispersión de material particulado (PM 10), con interrelación de factores meteorológicos y topográficos. Revistas Uptc, 8. ASHRAE. (2007). Ventilacion para una Calidad Aceptable de Aire Interior. Atlanta.es_ES
dc.source.bibliographicCitationObtenido de http://www.ditar.cl/archivos/Normas_ASHRAE/T0120ASHRAE62.1-2007-sp-Ventil-p-CAAI.pdfes_ES
dc.source.bibliographicCitationBaena Salazar, D., Jiménez, J. F., Zapata, c. E., & Ramírez Cardona, A. (2019). Artificial neural network applied for the forecast of critical PM2.5 events in the Aburra Valley. Dyna, 7.es_ES
dc.source.bibliographicCitationBarraza Villarreal, C. A., & Sánchez Quintero, L. M. (2019). Evaluación de la concentración de material particulado PM10 en la región Norte Centro histórico de la ciudad de Barranquilla. Barranquilla: Unicostaes_ES
dc.source.bibliographicCitationBarrera Torres, D. C. (2018). Evaluación de la calidad del aire interior mediante indicadores ecológicos y sociales asociados a la inmisión de material particulado (PM10) en el área de madera del taller de diseño industrial, Universidad el Bosque, sede Usaquén, periodo 2018-2. Bogotá: Universidad el Bosque.es_ES
dc.source.bibliographicCitationBeleño, R., Quijano P, A., & Meléndez G, I. (2013). Actividad mutagénica y genotóxica del material particulado PM2.5 en Cúcuta, Colombia. MVZ Córdoba, 14.es_ES
dc.description.degreenameIngeniero(a) Industriales_ES
dc.description.degreelevelPregradoes_ES
dc.publisher.facultyFacultad de Ingeniería Industriales_ES
dc.description.notesPresenciales_ES
dc.creator.cedula20411624298, 20411616204es_ES
dc.publisher.campusVillavicencioes_ES
dc.description.degreetypeMonografíaes_ES
Aparece en las colecciones: Ingeniería industrial

Ficheros en este ítem:
Fichero Tamaño  
2021_1_PG_Alarcon, C. y Poveda, S..pdf3.06 MBVisualizar/Abrir
ActaAlejandroAlarcon.pdf
  Restricted Access
607.12 kBVisualizar/Abrir  Request a copy
2021AutorizacióndeAutores.pdf
  Restricted Access
225.44 kBVisualizar/Abrir  Request a copy
ActaSebastianGuarin.pdf
  Restricted Access
928.94 kBVisualizar/Abrir  Request a copy
2021AutorizacióndeAutores.pdf
  Restricted Access
838.85 kBVisualizar/Abrir  Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.