Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.uan.edu.co/handle/123456789/7541
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Molina Gallego, Carlos Martin | - |
dc.creator | Riaño León, Jeisson Orlando | - |
dc.date.accessioned | 2023-02-14T21:28:19Z | - |
dc.date.available | 2023-02-14T21:28:19Z | - |
dc.date.created | 2022-05-30 | - |
dc.identifier.uri | http://repositorio.uan.edu.co/handle/123456789/7541 | - |
dc.description.abstract | The present work has several purposes, one of them is to show part of the history of the company Polimix Colombia, its economic activity, portfolio among other relevant data. Similarly, documenting the work of production of ready-mix concrete during professional practices, where the quality control of concrete in plant and on site was analyzed by means of taking settlements and making cylinders, in the same way and with the support of the quality area , the cement water relationship was monitored, observing how the resistance at mature age (28 days) would be affected if the standardized conditions were modified and the quality of the raw materials used for the same purpose was verified, a process that was carried out with the taking of laboratory tests, such as absorptions, humidity and density. | es_ES |
dc.description.tableofcontents | El presente trabajo tiene varios propósitos, uno de ellos es mostrar parte de la historia de la compañía Polimix Colombia, su actividad económica, portafolio entre otros datos relevantes. De igual forma, documentar la labor de producción de concreto premezclado durante las prácticas profesionales, donde se analizó el control de calidad del concreto en planta y en obra por medio de toma de asentamientos y elaboración de cilindros, de la misma manera y con el apoyo del área de calidad se llevó un seguimiento a la relación agua cemento, observando cómo se afectaría la resistencia a edad madura (28 días) si las condiciones estandarizadas se modificaran y se verificó la calidad de las materias primas utilizadas para el mismo fin, proceso que se realizó con la toma de ensayos de laboratorio, tales como absorciones, humedad y densidad. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad Antonio Nariño | es_ES |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.subject | Nsr10-Concreto Premezclado | es_ES |
dc.subject | Control De Calidad-Resistencia Del Concreto | es_ES |
dc.subject.ddc | T48.23 R481p | es_ES |
dc.title | Pasantías en planta fabricadora de hormigón | es_ES |
dc.type | Tesis - Trabajo de grado - Monografia - Pregrado | es_ES |
dc.publisher.program | Ingeniería Civil | es_ES |
dc.rights.accesRights | openAccess | es_ES |
dc.subject.keyword | Nsr10-Ready-Mixed | es_ES |
dc.subject.keyword | Concrete-Quality Control-Concrete Strength | es_ES |
dc.type.spa | Trabajo de grado (Pregrado y/o Especialización) | es_ES |
dc.type.hasVersion | info:eu-repo/semantics/acceptedVersion | es_ES |
dc.source.bibliographicCitation | B, H. (Noviembre de 1998). scielo.conicyt.cl. Obtenido de https://scielo.conicyt.cl/scielo.php?script=sci_nlinks&ref=9191525&pid=S0718- 5073201000020000300009&lng=es | es_ES |
dc.source.bibliographicCitation | Chun, B.-W. D. (2006). The Development of Cement and Concrete Additive Based on Xylonic Acid Derived Via Bioconversion of Xylose ‡. Humana Press Inc.All rights of any nature whatsoever reserved. | es_ES |
dc.source.bibliographicCitation | Económico, M. d. (2000). ADITIVOS QUÍMICOS PARA CONCRETO NTC 1299. SANTAFÉ DE BOGOTÁ: ICONTEC. | es_ES |
dc.source.bibliographicCitation | ECONOMICO, M. D. (2000). PRODUCCIÓN DE CONCRETO. SANTAFÉ DE BOGOTÁ : ICONTEC. | es_ES |
dc.source.bibliographicCitation | Huanca, S. (Marzo de 2006). Diseño de Mezclas de Concreto. Obtenido de Universidad Nacional del Altiplano: https://www.academia.edu/6006304/Universidad_Nacional_del_Altiplano_Dise% C3%B1o_de_Mezclas_de_Concreto | es_ES |
dc.source.bibliographicCitation | ICONTEC. (2001). AGUA PARA LA FABRICACIÓN DEL CONCRETO NTC 3459. Santa fe de Bogotá: ICONTEC. | es_ES |
dc.source.bibliographicCitation | ICONTEC, I. C. (1995). INGENIERÍA CIVIL Y ARQUITECTURA NTC 93. SANTAFÉ DE BOGOTÁ: ICONTEC. | es_ES |
dc.source.bibliographicCitation | Maria Patricia León, F. R. (2010). Caracterización morfológica de agregados para concreto mediante el análisis de imágenes. Revista ingeniería de construcción. | es_ES |
dc.source.bibliographicCitation | Polimix. (2019). Polimix. Obtenido de https://polimix.com.co/polimix_colombia/ | es_ES |
dc.source.bibliographicCitation | Steven H. Kosmatka, B. K. (2004). Diseño y Control de Mezclasde Concreto. EE.UU.: Portland Cement Association | es_ES |
dc.description.degreename | Ingeniero(a) Civil | es_ES |
dc.description.degreelevel | Pregrado | es_ES |
dc.publisher.faculty | Facultad de Ingeniería Civil | es_ES |
dc.audience | Especializada | es_ES |
dc.description.notes | Presencial | es_ES |
dc.creator.cedula | 10481719064 | es_ES |
dc.publisher.campus | Bogotá - Sur | es_ES |
dc.description.degreetype | Pasantía | es_ES |
Aparece en las colecciones: | Ingeniería civil |
Ficheros en este ítem:
Fichero | Tamaño | |
---|---|---|
2023_Jeisson Orlando Riaño León_Acta.pdf Restricted Access | 191.68 kB | Visualizar/Abrir Request a copy |
2023_Jeisson Orlando Riaño León_Autorizacion.pdf Restricted Access | 1.98 MB | Visualizar/Abrir Request a copy |
2023_Jeisson Orlando Riaño León.pdf | 1.88 MB | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons