dc.description.abstractImproving activated sludge systems (CAS) for wastewater treatment is a need that has been reflected in recent years. One of the main limitations of the CAS are the high energy consumption associated with mechanical aeration, being between 40-90% of the total energy consumption of the system. For this reason, the objective of this study was to evaluate the influence of fine bubble aeration (BF) on mass transfer and growth rate in a laboratory-scale activated sludge system. The results showed that the mass transfer coefficient (Kla) was much higher in the system with BF (0.0283 s-1), with respect to the system using conventional aeration (0.0111 s-1) indicating an improvement in O2 transfer. Furthermore, based on the literature and the Kla obtained for the BF system, they were classified as Microbubbles (MB). On the other hand, microbial growth showed a significant increase using the MB system umax = 6,789 d-1, indicating the influence of oxygen transfer on the growth rate of microorganisms. In addition, the simulation of the system used, the Monod kinetics, showed a low influence of the affinity coefficient (Ks) on the speed of substrate consumption and also a higher speed of substrate consumption in the MB system with respect to conventional aeration. . The MB system also showed a greater capacity to treat high concentrations of COD in less time (2.3 Kg COD / m3 in 2 hours) compared to the conventional system. Finally, the microbiology associated with the system presented different microorganisms such as protozoa, rotifers and the absence of filamentous bacteria, which indicates a good functioning of the activated sludge system. These results show the importance and influence of mass transfer on the kinetic parameters and consequently on the behavior of the reactor, guaranteeing the removal of pollutants from the waste water in less time and reducing the energy cost associated with conventional aeration.es_ES
dc.description.sponsorshipOtroes_ES
dc.description.tableofcontentsMejorar los sistema lodos activados (CAS) para el tratamiento de agua residual es una necesidad que se ha visto reflejada en los últimos años. Una de las principales limitaciones de los CAS son el alto consumo energético asociado a la aireación mecánica siendo entre el 40-90% del consumo energético total del sistema. Por está razón, el objetivo de este estudio fue evaluar la influencia de la aireación con burbujas finas (BF) sobre la transferencia de masa y velocidad de crecimiento en un sistema de lodos activados a escala laboratorio. Los resultados mostraron que el coeficiente de transferencia de masa (Kla) fue mucho mayor en el sistema con BF (0.0283 s-1), con respecto al sistema usando aireación convencional (0.0111 s-1) indicando una mejora en la transferencia de O2. Además, con base en la literatura y el Kla obtenido para el sistema con BF, se clasificaron como Microburbujas (MB). Por otra pate, el crecimiento microbiano mostró un aumento significativo usando el sistema de MB umax = 6.789 d-1, indicando la influencia de la transferencia de oxígeno sobre la tasa de crecimiento de los microorganismos. Además, la simulación del sistema empleado la cinética de Monod mostró, una baja influencia del coeficiente de afinidad (Ks) sobre la velocidad de consumo de sustrato y así mismo una mayor velocidad de consumo de sustrato en el sistema de MB con respecto al aireado convencionalmente. El sistema con MB mostró también una mayor capacidad de tratar altas concentraciones de DQO en menor tiempo (2.3 Kg DQO/m3 en 2 horas) con respecto al sistema convencional. Finalmente, la microbiología asociada al sistema presentó diferentes microorganismos como protozoarios, rotíferos y ausencia de bacterias filamentosas lo cual indica un buen funcionamiento del sistema de lodos activos. Estos resultados muestran la importancia e influencia de la transferencia de masa sobre los parámetros cinéticos y por consiguiente sobre el comportamiento del reactor, garantizando la remoción de contaminantes del 11 agua residual en menor tiempo y disminuyendo el costo energético asociado a la aireación convencional.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.rightsAtribución-SinDerivadas 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/us/*
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.subjectTransferencia de masaes_ES
dc.subjectparámetros cinéticoses_ES
dc.subjectBurbujas finases_ES
dc.subjectOxígeno disueltoes_ES
dc.subjectLodos activadoses_ES
dc.titleEstimación del Coeficiente de Transferencia de Masa (KLa) y los parámetros cinéticos empleando la metodología de respirometría en un sistema de lodos activados con burbujas finases_ES
dc.publisher.programIngeniería Ambientales_ES
dc.rights.accesRightsrestrictedAccesses_ES
dc.subject.keywordMass transferes_ES
dc.subject.keywordkinetic parameterses_ES
dc.subject.keywordFine bubbleses_ES
dc.subject.keywordDissolved oxygenes_ES
dc.subject.keywordActivated sludgees_ES
dc.type.spaTrabajo de grado (Pregrado y/o Especialización)es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.source.bibliographicCitationAmann, R., Lemmer, H., & Wagner, M. (1998). Monitoring the community structure of wastewater treatment plants: A comparison of old and new techniques. FEMS Microbiology Ecology, 25(3), 205–215.es_ES
dc.source.bibliographicCitationArcos,Y. (2013) microbiología de lodos activados., Universidad de Antioquia., Hechos microbiol,177-122.es_ES
dc.source.bibliographicCitationAPHA, AWWA and WPCF (2005) Standard Methods for the Examination of Water and Wastewater. American Public Health Association, Washington DC.es_ES
dc.source.bibliographicCitationBalcárcel,L.,Erazo,P.,Vides,M & Ramirez,a. (2012) Parametros fisicoquímicos asociados a la proliferación de bacterias filamentosas (bulking filamentoso) en las plantas de tratamiento de aguas residuales mediante lodos activados:revisión sistematica.,Universidad de Antioquia.,Hechos microbiol 47-58.es_ES
dc.source.bibliographicCitationBao-hong, G, Zhing-biao,W, & Liang,X. (2003) kinetics of aerobically activated sludge on terylene artificial silk printing and dyeing wastewater treatment. Journal of Zhejiang university SCIENCE. 441-449es_ES
dc.source.bibliographicCitationBenetti, A. D., & Aquino, S. F. (2010). Aplicação de princípios de bioenergética no cálculo da estequiometria de reações biológicas em processos de tratamento de águas residuárias. Engenharia Sanitaria e Ambiental, 15(3), 245–250. https://doi.org/10.1590/s1413-41522010000300007 .es_ES
dc.source.bibliographicCitationBerrocal, I. J. M. (2011). Principios de la Transferencia de Masa en la Ingeniería de Alimentos.es_ES
dc.source.bibliographicCitationBredwell, M. D., & Worden, R. M. (1998). Mass-transfer properties of microbubbles. 1. Experimental studies. Biotechnology Progress, 14(1), 31–38. https://doi.org/10.1021/bp970133x.es_ES
dc.source.bibliographicCitationCalifornia wáter boards,state water resources control board, Folleto Informativo 3.1.1.0.es_ES
dc.source.bibliographicCitationComisión nacional de agua, S. (2010). Manual de Agua Potable , Alcantarillado y Saneamiento Manual de Agua Potable , Alcantarillado y Saneamiento Operación y Mantenimiento de Plantas Municipales : Lodos Activados. 242.es_ES
dc.source.bibliographicCitationChan, Y.J., Chong;M.F.,Law,L.C., & Hassell,D.G. (2009). a review on anaerobic-aerobic treatment of industrial and municipal wastewater. Chemical engineering journal. 155(1-2):1-18. DOI: 10.1016/j.cej.2009.06.041.es_ES
dc.source.bibliographicCitationDorian, M.P. (2013) Bioprocces engineering principles. Elsevier. 2nd ed. ISBN 978-0-12-220851-5es_ES
dc.source.bibliographicCitationDionisi, D. (2017). Biological Wastewater Treatment Processes. In Biological Wastewater Treatment Processes. https://doi.org/10.1201/9781315163345-2.es_ES
dc.source.bibliographicCitationDu,X, Wang,J.,Jegatheesan,V., & Shi,G. (2018) Dissolved oxygen control in activated sludge process using a neural network-based adaptive PID algorithm. Applied sciences. DOI:10.3390/app8020261.es_ES
dc.source.bibliographicCitationDrewnowski, J., Remiszewska-Skwarek, A., Duda, S., & Łagód, G. (2019). Aeration process in bioreactors as the main energy consumer in a wastewater treatment plant. Review of solutions and methods of process optimization. Processes, 7(5). https://doi.org/10.3390/pr7050311.es_ES
dc.source.bibliographicCitationEscalante,V.,Ramirez,E.,Pozo,F.,Cardoso,L.,Tomasini,A.,Moeller,G. (2006)Operación y mantenimiento de plantas de tratamiento de lodos activados., Instituto mexica de tecnología del agua. Primera edición.es_ES
dc.source.bibliographicCitationEstrada-Vázquez, C., Salinas-Pacheco, A., Peralta-Reyes, E., Poggi-Varaldo, H. M., & Regalado-Méndez, A. (2019). Parametric optimization of domestic wastewater treatment in an activated sludge sequencing batch reactor using response surface methodology. Journal of Environmental Science and Health, Part A, 0(0), 1–9. https://doi.org/10.1080/10934529.2019.1631087.es_ES
dc.source.bibliographicCitationFavaro,A.,Rosa,C.(2018) 9 passos infaliveis para aumentar o desempenho de sua ETE sem aumentar os custos.WWW.acquaexpert.com.es_ES
dc.source.bibliographicCitationFerrer, J., Seco, A., Serralta, J., Ribes, J., Manga, J., Asensi, E., Morenilla, J.J & Llavador, F. (2008).,DESASS: una herramienta de software para diseñar, simular y optimizar las PTAR.,Reinar. Modelo. Softw , 23 ( 2008 ) , págs. 19 – 26.es_ES
dc.source.bibliographicCitationGalaction A., Cascaval D., Oniscu C & Turnea M. (2004) Prediction of oxygen mass transfer coefficients in stirred bioreactors for bacteria, yeasts and fungus broths. Biochemical Engineering Journal. 20(1): 85–94.es_ES
dc.source.bibliographicCitationGil, M. (2006). Depuración de aguas residuales: modelización de procesos de lodos activos. Madrid, ES: Editorial CSIC ,Consejo Superior de Investigaciones Científicas.es_ES
dc.source.bibliographicCitationHenze, M., Gujer, W., Mino, T., & van Loosedrecht, M. (2015). Activated Sludge Models ASM1, ASM2, ASM2d and ASM3. Water Intelligence Online, 5(0), 9781780402369–9781780402369. https://doi.org/10.2166/9781780402369.es_ES
dc.source.bibliographicCitationHenze,M.,Gujer,W.,Mino,T & Van Loosdrecht,M. (2000) Activated sludge moodels ASM1,ASM2, ASM2d and ASM3., Iwa task group on mathematical modelling for design and operation of biological wastewater treatment.es_ES
dc.source.bibliographicCitationHu, L., Wu, X., Liu, Y., Meegoda, J. N & Gao, S. (2010) Physical Modeling of Air Flow During Air Sparging Remediation. Environ. Water Sci.Technol., 44, 3883–3888.es_ES
dc.source.bibliographicCitationKapeler,J., W. Gujer (1992) Estimation of Kinetic Parameters of Heterptrophic Biomass Under Aerobic Conditions and Characterisation of Wastewater for Activated Sludge Modeling. Water Sci. Technol.., 25, ( 6), 125.es_ES
dc.source.bibliographicCitationKarlikanovaite-Balikci, A., & Yagci, N. (2019). Determination and evaluation of kinetic parameters of activated sludge biomass from a sludge reduction system treating real sewage by respirometry testing. Journal of Environmental Management, 240(March), 303–310. https://doi.org/10.1016/j.jenvman.2019.03.131.es_ES
dc.source.bibliographicCitationLeón J. (2018) Diseño, implementacion y evaluacion de un sistema de lodos activados en operación continua a través de un prototipo automático funcional a escala (Tesis pregrado), Universidad Antonio Nariño, Bogotá-Colombia.,Pag24-25.es_ES
dc.source.bibliographicCitationLevin, M.A., & Gealt, M.A. (Eds.). (1993). Biotreatment of industrial and hazardous waste. United States: McGraw-Hill, Inc.es_ES
dc.source.bibliographicCitationLi, H., Hu, L., Song, D., & Lin, F. (2015). Characteristics of Micro-Nano Bubbles and Potential Application in Groundwater Bioremediation. Water Environment Research, 86(9), 844–851. https://doi.org/10.2175/106143014x14062131177953.es_ES
dc.source.bibliographicCitationMadoni, P. (2011). Protozoa in wastewater treatment processes: A minireview. Italian Journal of Zoology, 78(1), 3–11.es_ES
dc.source.bibliographicCitationMallqui,E.A.(2019). Evaluación de la velocidad de transferencia de oxígeno, en un sistema de aireacion de agua ( tesi para optar grado académico de Maestro en Ingeniería química) .Universidad nacional del centro de Perú. Escuela de posgrado de la facultad de ingeniería químicaes_ES
dc.source.bibliographicCitationMéndez, L., Miyashiro, V., Rojas, R., Cotrado, M., & Carrasco, N. (2004). Tratamiento De Aguas Residuales Mediante Lodos Activados a Escala De Laboratorio. Revista Del Instituto de Investigación FIGMMG,Pag 2, 74–83.es_ES
dc.source.bibliographicCitationMetcalf & Eddy. (2003)Wastewater Engineering: Treatment and Reuse (4th ed.), McGraw-Hill, Boston, USA.es_ES
dc.source.bibliographicCitationMoeller,G.,Tomasini,A.(2004)Memorias curso internacional de sistemas integrados de tratamiento de aguas residuales., Cap 2-5 microbiologia de lodos activados.,IDEAM.es_ES
dc.source.bibliographicCitationPainmanakul, P., Loubière, K., Hébrard, G., Mietton-Peuchot, M. & Roustan, M.(2005).Effect of surfactants on liquid-side mass transfer coefficients. Chemical Engineering Science 60 (22), 6480–6491.es_ES
dc.source.bibliographicCitationPajdak-Stós, A., Kocerba-Soroka, W., Fyda, J., Sobczyk, M., & Fiałkowska, E. (2017). Foam-forming bacteria in activated sludge effectively reduced by rotifers in laboratory- and real-scale wastewater treatment plant experiments. Environmental Science and Pollution Research, 24(14), 13004–13011.es_ES
dc.source.bibliographicCitationRangel L, e. a. (2007). Análisis y caracterización de bacterias heterotrofas.es_ES
dc.source.bibliographicCitationRogel Dorantes, J. A. (2013). Determinación de los parámetros cinéticos de un lodo-modelo para estudiar la minimización de los sólidos, en un proceso biológico de tratamiento de agua residual. 112.es_ES
dc.source.bibliographicCitationRollemberg, S. L. de S., Barros, A. N. de, Lira, V. N. S. A., Firmino, P. I. M., & dos Santos, A. B. (2019). Comparison of the dynamics, biokinetics and microbial diversity between activated sludge flocs and aerobic granular sludge. Bioresource Technology, 294(July), 122106. https://doi.org/10.1016/j.biortech.2019.122106.es_ES
dc.source.bibliographicCitationSladecek, V. (1983). Rotifers as Indicators of Water Quality. Hydrobiologia, 100, 169–201es_ES
dc.source.bibliographicCitationSoler,A.,Buitrago,G. (2010). Evaluación de la transferencia de oxígeno en cultivos con lactoccus lactis empleando un sistema de fermentación con aireacion externa. Rev. Colomb. Biotecnol. 124-138.es_ES
dc.source.bibliographicCitationSpanjers, H., & Vanrolleghem, P. (1995). Respirometry as a tool for rapid characterization of wastewater and activated sludge. Water Science and Technology, 31(2), 105–114. https://doi.org/10.1016/0273-1223(95)00184-Oes_ES
dc.source.bibliographicCitationRaffo-Durán,J., Gigueredo-Cardero,A., & Dustet-Mendoza ,J.C. (2014). Caracteristicas de la hidrofinámica de un biorreactor industrial tipo tanque agitado. Revista mexicana de ingeniería química. Vol.13,No. 3. 823-839es_ES
dc.source.bibliographicCitationTrojanowicz, W., Styka, W., & Baczynski, T. (2009). Experimental determination of kinetic parameters for heterotrophic microorganisms in bioflim under petrochemical wastewater conditions. Polish Journal of Environmental Studies, 18(5), 913–921.es_ES
dc.source.bibliographicCitationVanrolleghem, P., Spanger, H., Petersen, B., Ginestest, P. y Takács, I. (1999). Estimating (combination of) activated sludge model No. 1 parameters and components by respirometry. Water Sciencie and Technology 39, 195-214.es_ES
dc.source.bibliographicCitationVilaseca Vallvè, M. M. (2001). Observación microscópica de fangos activados en los tratamientos De depuración biológica. Boletin Intexter Del Instituto de Investigacion Textil y de Cooperacion Industrial, (119), 67–74es_ES
dc.source.bibliographicCitationVon Sperling, M. (2015). Wastewater Characteristics, Treatment and Disposal. In Water Intelligence Online (Vol. 6). https://doi.org/10.2166/9781780402086.es_ES
dc.source.bibliographicCitation-Wongsuchoto, P., Charinpanitkul, T., & Pavasant, P. (2003). Bubble size distribution and gas-liquid mass transfer in airlift contactors. Chemical Engineering Journal, 92(1–3), 81–90. https://doi.org/10.1016/S1385-8947(02)00122-5es_ES
dc.source.bibliographicCitationYao Kangning, Yong Chi, Fei Wang, Jianhua Yan, Mingjiang Ni y Kefa C.(2016) The effect of microbubbles on gas-liquid mass transfer coefficient and degradation rate of COD in wastewater treatment. Water science & techinology 73.8.es_ES
dc.description.degreenameIngeniero(a) Ambientales_ES
dc.description.degreelevelPregradoes_ES
dc.publisher.facultyFacultad de Ingeniería Ambientales_ES
dc.description.notesPresenciales_ES
dc.creator.cedula1012409495es_ES
dc.creator.cedula91158810es_ES
dc.creator.cedula1013665372es_ES
dc.publisher.campusBogotá - Sur-
Aparece en las colecciones: Ingeniería ambiental

Ficheros en este ítem:
Fichero Tamaño  
2020JeisonAriasRátiva.pdf1.83 MBVisualizar/Abrir
2020AutorizaciondeAutores.pdf
  Restricted Access
7.46 MBVisualizar/Abrir  Request a copy


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons