dc.description.abstractIn the present work, a study was carried out to determine the corrosion resistance of the anodized and thermally oxidized Ti6Al4V alloy for biomedical applications. To carry out the study, light microscopy (OM), anodizing, thermal oxidation in a furnace, corrosion potentials and potentiodynamic polarization curves were performed. In the anodizing test procedure, constant conditions were detected in the samples, but varying the thermal oxidation temperatures from 520 ° C, 560 ° C and 600 ° C. Initially, the results of the microstructures of the material in the cross sections and longitudinal where the α and β phases are observed which are responsible for the mechanical behaviors, high temperatures, resistance to corrosion and biocompatibility. In terms of corrosion, check the open potential curves where the indicated samples are found to have superior behavior with respect to the metal base and in some samples, superior behavior to the others. This was directly related to thermal oxidation temperatures. Two important results were observed in the potentiodynamic curves, the behavior of the anodic and cathodic branches of the samples tested and the rate of corrosion. The above showed that the sample oxidized at 520 ° C showed a better corrosion behavior and a lower corrosion rate compared to the others. Finally, as a conclusion of the project, the thermally improved oxidized samples were determined, the resistance to corrosion at different temperatures with respect to the metal base, this increases the biocompatibility for biomedical systems or applications.es_ES
dc.description.sponsorshipOtroes_ES
dc.description.tableofcontentsEn el presente trabajo se realizó un estudio para determinar la resistencia a la corrosión de la aleación Ti6Al4V anodizada y oxidada térmicamente para aplicaciones biomédicas. Para la realización del estudio se realizaron ensayos de microscopía óptica (MO), anodizado, oxidación térmica en un horno, potenciales de corrosión y curvas de polarización potenciodinámicas. En el procedimiento de los ensayos de anodizado se mantuvo las condiciones constantes en las muestras, pero variando las temperaturas de oxidación térmica desde 520°C, 560°C y 600°C. Inicialmente los resultados mostraron las microestructuras del material en las secciones transversal y longitudinal donde se observaron las fases α y β las cuales son las responsables de los comportamientos mecánicos, de altas temperaturas, resistencia a la corrosión y biocompatibilidad. En términos de corrosión, se observó inicialmente las curvas de potencial abierto donde se las muestras presentaron un comportamiento superior respecto al metal base y en algunas muestras comportamientos superiores a las otras. Lo anterior se relacionó directamente con las temperaturas de oxidación térmica. En las curvas potenciodinámicas se observaron 2 resultados importantes, el comportamiento de las ramas anódicas y catódicas de las muestras ensayadas y la velocidad de corrosión. Lo anterior mostró que la muestra oxidada a 520°C mostró un mejor comportamiento a corrosión y una tasa de corrosión más baja respecto a las otras. Finalmente, como conclusión del proyecto se determinó que las muestras oxidadas térmicamente mejoran sustancialmente la resistencia a la corrosión en las diferentes temperaturas respecto al metal base, esto hace que la biocompatibilidad para sistemas o aplicaciones biomédicas aumente.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.rightsAtribución 3.0 Estados Unidos de América*
dc.rightsAtribución 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/us/*
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.subjectAnodizadoes_ES
dc.subjectOxidación térmicaes_ES
dc.subjectCorrosiónes_ES
dc.subjectTi6Al4Ves_ES
dc.titleEvaluación de la resistencia a la corrosión de la aleación Ti6AI4V modificadas mediante oxidación térmicaes_ES
dc.publisher.programIngeniería Mecánicaes_ES
dc.rights.accesRightsopenAccesses_ES
dc.subject.keywordAnodizedes_ES
dc.subject.keywordThermal oxidationes_ES
dc.subject.keywordCorrosiones_ES
dc.subject.keywordTi6Al4Ves_ES
dc.type.spaTrabajo de grado (Pregrado y/o Especialización)es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.source.bibliographicCitationAl-Mayman, S. I., Al-Abbadi, N. M., & Muataz, A. A. (2014). Thermal Oxidation Kinetic of Carbon Nanotubes (CNTs). Chemical Engineeing, 621–630.es_ES
dc.source.bibliographicCitationBiswas, A., Manna, I., Chatterjee, U., Bhattacharyya, U., & Dutta-Majumdar, J. (2009). Evaluation of electrochemical properties of thermally oxidised Ti–6Al–4V for bioimplant application. Surface Engineering, 141-145.es_ES
dc.source.bibliographicCitationCaballis-Caballero, C., & Rodriguez-Cespedes, R. (2015). Determinación del comportamiento a la corrosion bajo ambiente salino de las juntas soldadas por fricción y agitacion y fusion de aluminio AA1100-O. Barranquilla: Universidad Autónoma del Caribe.es_ES
dc.source.bibliographicCitationCely, M. (2013). Efecto de la modificación superficial de la aleación Ti6Al4V En condición de contacto lubricado con polietileno de ultra alto peso molecular (uhmwpe). Medellin: Universidad Nacional de Colombia.es_ES
dc.source.bibliographicCitationCely, M.-M., Castellar, G., Pereira, J., & Ángel, R. (2018). Efecto de la velocidad de calentamiento sobre las propiedades mecánicas y resistencia a la corrosión de aleaciones de titanio modificadas. Ingeniare. Revista chilena de ingeniería, 577-584.es_ES
dc.source.bibliographicCitationChen, X., & Mao, S. (2007). Titanium Dioxide Nanomaterials:  Synthesis, Properties, Modifications, and Applications. California: American Chemical Society.es_ES
dc.source.bibliographicCitationConcha-Guzman, M.-O., Gonzalez, R., & Cuevas-Arteaga, C. (2012). omparación de técnicas electroquímicas dinámicas y estáticas en la elaboración de nanoestructuras de TiO2 a bajo potencial. Superficie y Vacío, 25, 1-13.es_ES
dc.source.bibliographicCitationConcha-Guzman, M.-O., Reynaud Morales, A., & Cuevas-Arteaga, C. (2010). Crecimiento De Nanoestructuras De TIO2 Obtenidas Por Reacción Anódica En Soluciones Ácidas H2SO4/HF. Superficies y Vacío, 183-187.es_ES
dc.source.bibliographicCitationDavis, J. (1999). ASM Specialty Handbook: Heat-Resistant Materials. United Satates of America: ASM International.es_ES
dc.source.bibliographicCitationDel Hierro, I., & Pérez, Y. (2015). Alcoxisilanos en la consolidación de materiales pétreos. Otras ciencias y técnicas aplicadas en arqueología, 171-180.es_ES
dc.source.bibliographicCitationFamiliant, Y., Corzine, K., Huang, J., & Belkhayat, M. (2005). AC Impedance Measurement Techniques. IEEE International Conference on Electric Machines and Drives, 1850-1857.es_ES
dc.source.bibliographicCitationFernandes, J. A., Kohlrausch, E. C., Khan, S., Brito, R. C., Machado, R. C., Teixeira, S. R., . . . Leite Santos, M. J. (2017). Effect of anodisation time and thermal treatment temperature on the structural and photoelectrochemical properties of TiO2 nanotubes. Journal of Solid State Chemistry, 1-21.es_ES
dc.source.bibliographicCitationGarcía-Minguillán, D. (2009). Nitruración de la aleación Ti6Al4V en capas superficiales usando energía solar concentrada mediante una lente de fresnel para obtener recubrimientos protectores de características superconductoras. Ciudad Real: Escuela Técnica Superior de Ingenieros Industriales de Ciudad Real .es_ES
dc.source.bibliographicCitationGil, F., & Planell, J. (1993). Aplicaciones biomédicas del titanio v sus aleaciones . Biomecánica-Originales, 34-42.es_ES
dc.source.bibliographicCitationGuleryuz, H., & Cimenoglu, H. (2004). Effect of thermal oxidation on corrosion and corrosion–wear behaviour of a Ti–6Al–4V alloy. Biomaterials, 3325–3333.es_ES
dc.source.bibliographicCitationHernandez Lopez, J. M. (2015). Funcionalización superficial de aleaciones de titanio mediante anodizado para aplicaciones biomédicas. Madrid: Universidad Autónoma de Madrid.es_ES
dc.source.bibliographicCitationHernandez, G. (2017). Desarrollo de Películas Hidrofóbicas en Aluminio Mediante la Técnica de Anodizado. México: Universidad Nacional Autónoma de México .es_ES
dc.source.bibliographicCitationKhidhir, B. A., Mustafa Ahmed, Y., Sahari, K., & Ishak, M. (2014). Titanium and its Alloy. International Journal of Science and Research (IJSR), 1351-1361.es_ES
dc.source.bibliographicCitationKumar, S., Narayanan Tsn, S., Sundara Raman, S. G., & Seshadri, S. K. (2010). Surface modification of CP-Ti to improve the fretting-corrosion resistance: Thermal oxidation vs. anodizing. Materials Science and Engineering C, 921-927.es_ES
dc.source.bibliographicCitationLijima, S. (1991). Helical microtubules of graphitic carbon. Nature, 56–58.es_ES
dc.source.bibliographicCitationLonghitano, G., Maria-Angeles, A., Conde, A., Larosa, M., André, J., Jardiní, A., . . . Damborenea, J. (2018). Heat treatments effects on functionalization and corrosion behavior of Ti-6Al-4V ELI alloy made by additive manufacturing. Alloys and Compounds, 961-968.es_ES
dc.source.bibliographicCitationM, J., Sankara-Narayanan, T., & Chu, P. K. (2013). Thermal oxidation of titanium: Evaluation of corrosion resistance as a function of cooling rate. Materials Chemistry and Physics , 1-8.es_ES
dc.source.bibliographicCitationMacak, J., Tsuchiya, H., Ghicov, A., Yasuda, K., Hahn, R., Bauer, S., & Schmuki, P. (2007). TiO2 nanotubes: Self-organized electrochemical formation, properties and applications. Solid state and material science, 3-18.es_ES
dc.source.bibliographicCitationOsorio, D. (2017). Estudio de la corrosión sufrida a altas temperaturas por sales fundidas en aceros para caldera tipo ASTM A193 y ASTM A53. Pereira: Universidad tecnológica de Pereira.es_ES
dc.source.bibliographicCitationPalacio, L. A. (2004). Métodos de síntesis de nuevos materiales basados en metales de transición. Revista Facultad de Ingeniería Universidad de Antioquia, 51-61.es_ES
dc.source.bibliographicCitationPereyra, M., & Méndez, E. (2011). Nanotubos de orientación vertical autoensamblados por método electroquímico: síntesis y caracterización. Universidad de la República, 45-49.es_ES
dc.source.bibliographicCitationRomero, R., & Rodriguéz, J. (2012). Evaluación del efecto de la temperatura de anodizado sobre la respuesta tribológica de recubrimientos anódicos sobre la aleación Ti6Al4V. Santander: Universidad Industrial de Santander.es_ES
dc.source.bibliographicCitationRoy, P., Berger, S., & Schmuki, P. (2011). TiO2 Nanotubes: Synthesis and Applications. NanoScience, 2904-2939.es_ES
dc.source.bibliographicCitationShajesh, P. (2009). Organically Modified Sol-Gel Derived Organically Modified Sol-Gel Derived Aerogels Through Ambient Pressure Drying. Cochín: Cochín University of Science and Technology, Cochin.es_ES
dc.source.bibliographicCitationSharmila Devi, R., Rajendran, V., & Sivaraj, R. (2014). Synthesis of Titanium Dioxide Nanoparticles by Sol-Gel Technique. International Journal of Innovative Research in Science, Engineering and Technology, 15206-15211.es_ES
dc.source.bibliographicCitationSmith F, W., & Hashemi, J. (2010). Fundamentos de la Ciencia e Ingeniería de Materiales. Mexico DF: McGraw-Hill .es_ES
dc.source.bibliographicCitationTolvanen, S. (2016). Microstructure and mechanical properties of Ti-6Al-4V welds produced with different processes. Materials Science, 50-62.es_ES
dc.source.bibliographicCitationTorregrosa, R., & Villareal, L. (17 de Febrero de 2008). Fundamentos de cinética de la corrosión y los diagramas de Evans. Obtenido de http://rua.ua.es/dspace/bitstream/10045/8231/1/CorrTema5.pdf.es_ES
dc.source.bibliographicCitationTristancho, J., Holguín, M., & Ramirez, L. (2015). Corrosión a alta temperatura de los recubrimientos metálicos NiCr y NiCrBSiFe depositados mediante proyección térmica. Prospectiva , 32-38.es_ES
dc.source.bibliographicCitationWang, S., Liao, Z. L., Liu, Y., & Liu, W. (2015). Influence of thermal oxidation duration on the microstructure and fretting wear behavior of Ti6Al4V alloy. Materials Chemistry and Physics, 1-13.es_ES
dc.source.bibliographicCitationWang, S., Liao, Z., Yuhong, L., & Weiqiang, L. (2014). Influence of thermal oxidation temperature on the microstructural and tribological behavior of Ti6Al4V alloy. Surface & Coatings Technology, 470-477.es_ES
dc.source.bibliographicCitationYang, J., Yang, H., Yu, H., Zeming, W., & Zeng, X. (2017). Corrosion Behavior of Additive Manufactured Ti-6Al-4V Alloy in NaCl Solution. Metallurgical and materials transactions A, 1-11.es_ES
dc.description.degreenameIngeniero(a) Mecánico(a)es_ES
dc.description.degreelevelPregradoes_ES
dc.publisher.facultyFacultad de Ingeniería Mecánica, Electrónica y Biomédicaes_ES
dc.description.funder$5.840.000 (de acuerdo a lo reportado en el anteproyecto): $1.040.000 (Propios) $4.800.000 (UAN)es_ES
dc.description.notesPresenciales_ES
dc.publisher.campusPuerto Colombia Barranquilla-
Aparece en las colecciones: Ingeniería mecánica

Ficheros en este ítem:
Fichero Tamaño  
2020Dayron.pdf2.95 MBVisualizar/Abrir
2020AutorizacióndeAutores. 1pdf
  Restricted Access
454.79 kBVisualizar/Abrir  Request a copy
2020AutorizacióndeAutores2.pdf
  Restricted Access
860.56 kBVisualizar/Abrir  Request a copy


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons