Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.uan.edu.co/handle/123456789/2522
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorFernández Periche, Francisco-
dc.creatorValencia Córdoba, Camilo Andres-
dc.date.accessioned2021-03-03T19:10:06Z-
dc.date.available2021-03-03T19:10:06Z-
dc.date.created2020-05-27-
dc.identifier.urihttp://repositorio.uan.edu.co/handle/123456789/2522-
dc.description.abstractThe project presented was carried out due to the fact that there is a limitation of rehabilitation machines that allow the legs to be held in order to perform cyclic movements as a therapy method, since the current ones do not have leg braces for paraplegic patients. With the above, a proposal was achieved that innovates in the field of mechanics applied to health, since a prototype was designed and built coupled to a four-bar system mechanism to hold a patient's legs. With the development of the prototype, it allows to hold the legs, keeping a parallelism. Likewise, Mr. Absalon Garcia participated as a base for our research in the city of Neiva (Huila), from where the initial data was taken for the working measurements of the mechanism, dimension of the four-bar system, areas of subjection; as ergonomic support points for its later tests. A proposal was defined which took into account the following variables such as turning speed, torque, length of four-bar mechanism, geometries for four bars, engine power, transmission ratio, selection of materials, bicycle mechanism and a four-bar system used to correct the posture of the legs. Where it was achieved by means of an electromechanical mechanism to join a four-bar mechanism to a bicycle mechanism. Achieving as a result a practical functional prototype to perform a specific exercise such as cyclical movements.es_ES
dc.description.tableofcontentsEl proyecto presentado se llevó a cabo debido a que existe una limitación de máquinas de rehabilitación que permita sujetar las piernas para realizar movimientos cíclicos como método de terapia, ya que las actuales no cuentan con sujetadores en las piernas de los pacientes con paraplejia. Con lo anterior se logró una propuesta que innova en el campo de mecánica aplicada a salud, se diseñó y se construyó un prototipo acoplado a un mecanismo de sistema cuatro barras para sujetar las piernas de un paciente. Con el desarrollo del prototipo permite sujetar las piernas, guardando un paralelismo. Así mismo se llevó a cabo la participación del Señor Absalón García como base de nuestra investigación en la ciudad de Neiva (Huila), de donde se tomaron los datos iniciales para las medidas de trabajo del mecanismo, dimensión del sistema cuatro barras, áreas de sujeción; como puntos de apoyo ergonómicos para sus posteriores pruebas. Se definió una propuesta el cual se tomó en cuenta las siguientes variables como velocidad de giro, torque, longitud de mecanismo cuatro barras, geometrías para cuatro barras, potencia del motor, relación de transmisión, selección de materiales, mecanismo bicicleta y un sistema cuatro barras usado para corregir la postura de las piernas. En donde se logró por medio de un mecanismo electromecánico unir un mecanismo cuatro barras a mecanismo bicicleta. Logrando como resultado un prototipo funcional practico para realizar un ejercicio en específico como lo son los movimientos cíclicos.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.rightsAtribución-CompartirIgual 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/us/*
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.subjectMecanismo bicicleta.es_ES
dc.subjectMecanismo cuatro barras.es_ES
dc.subjectEstabilidad.es_ES
dc.subjectMovimiento cíclico.es_ES
dc.titlePrototipo de mecanismo bicicleta electromecánica con corrector de postura cuatro barras para personas con discapacidad en extremidades inferiores.es_ES
dc.publisher.programIngeniería Mecánicaes_ES
dc.rights.accesRightsopenAccesses_ES
dc.subject.keywordBicycle mechanism.es_ES
dc.subject.keywordFour bars mechanism.es_ES
dc.subject.keywordStability.es_ES
dc.subject.keywordCyclic movement.es_ES
dc.type.spaTrabajo de grado (Pregrado y/o Especialización)es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.source.bibliographicCitationCorlett. 2013. «RULA: Rapid Upper Limb Assessment». 2013. /grupo/es/node/9.es_ES
dc.source.bibliographicCitation«Diseño de Elementos de Máquinas - 4ta Edición - Robert L. Mott.pdf». s. f.es_ES
dc.source.bibliographicCitation«Diseño en ingeniería mecánica de Shigley, 8va Edición - Richard G. Budynas-FREELIBROS.ORG.pdf». s. f.es_ES
dc.source.bibliographicCitationDonaldson, N.de N., M. Munih, G.F. Phillips, y T.A. Perkins. 2010. «Apparatus and Methods for Studying Artificial Feedback-Control of the Plantarflexors in Paraplegics without Interference from the Brain». Medical Engineering & Physics 19 (6): 525-35. https://doi.org/10.1016/S1350-4533(97)00020-9.es_ES
dc.source.bibliographicCitationEcured. 2009. «Información de “EcuRed:Enciclopedia cubana” - EcuRed». 2009. https://www.ecured.cu/index.php?title=EcuRed:Enciclopedia_cubana&action=info.es_ES
dc.source.bibliographicCitationFaupin, Arnaud, y Philippe Gorce. 2008. «The Effects of Crank Adjustments on Handbike Propulsion: A Kinematic Model Approach». International Journal of Industrial Ergonomics 38 (7-8): 577-83. https://doi.org/10.1016/j.ergon.2008.01.019.es_ES
dc.source.bibliographicCitationLamine, Houssein, Med Amine Laribi, Sami Bennour, Lotfi Romdhane, y Said Zeghloul. 2017. «Design Study of a Cable-Based Gait Training Machine». Journal of Bionic Engineering 14 (2): 232-44. https://doi.org/10.1016/S1672-6529(16)60394-3.es_ES
dc.source.bibliographicCitationLong, Yi, Zhijiang Du, Chaofeng Chen, Weidong Wang, Long He, Xiwang Mao, Guoqiang Xu, Guangyu Zhao, Xiaoqi Li, y Wei Dong. 2017. «Development and Analysis of an Electrically Actuated Lower Extremity Assistive Exoskeleton». Journal of Bionic Engineering 14 (2): 272-83. https://doi.org/10.1016/S1672-6529(16)60397-9.es_ES
dc.source.bibliographicCitationNorton. 2012. «Diseño de arboles y ejes».es_ES
dc.source.bibliographicCitationPiazza, Stefano, Julio Gómez-Soriano, Elisabeth Bravo-Esteban, Diego Torricelli, Gerardo Avila-Martin, Iriana Galan-Arriero, José Luis Pons, y Julian Taylor. 2016. «Maintenance of Cutaneomuscular Neuronal Excitability after Leg-Cycling Predicts Lower Limb Muscle Strength after Incomplete Spinal Cord Injury». Clinical Neurophysiology 127 (6): 2402-9. https://doi.org/10.1016/j.clinph.2016.03.007.es_ES
dc.source.bibliographicCitation«Poleas». s. f. Accedido 4 de abril de 2020. http://www.juntadeandalucia.es/averroes/centros-tic/41700555/helvia/aula/archivos/repositorio/0/4/html/poleas.htm.es_ES
dc.source.bibliographicCitationPoveda. 2016. «BICICLETA ESTÁTICA ERGONÓMICA PARA APLICACIÓN DE LA ACTIVIDAD DEPORTIVA EN EL GIMNASIO DE LA ESCUELA SUPERIOR POLITÉCNICA DEL CHIMBORAZO.», 55.es_ES
dc.source.bibliographicCitationQuintern, J., P. Minwegen, y K.-H. Mauritz. 2009. «Chapter 41 Control Mechanisms for Restoring Posture and Movements in Paraplegics». En Progress in Brain Research, 80:489-502. Elsevier. https://doi.org/10.1016/S0079-6123(08)62248-7.es_ES
dc.source.bibliographicCitation«Resistencia-de-Materiales-Robert-Mott.pdf». s. f.es_ES
dc.source.bibliographicCitation«resolucion-1441-de-2013.pdf». s. f.es_ES
dc.source.bibliographicCitation«resolucion-3100-de-2019.pdf». s. f.es_ES
dc.source.bibliographicCitationRiener, Robert, Jochen Quintern, y Günther Schmidt. 2009. «Biomechanical Model of the Human Knee Evaluated by Neuromuscular Stimulation». Journal of Biomechanics 29 (9): 1157-67. https://doi.org/10.1016/0021-9290(96)00012-7.es_ES
dc.source.bibliographicCitationSanchez, Luisa. 2015. «Escaras o úlceras por presión». Blog de ortopedia de ortoweb.com (blog). 2015. http://www.ortoweb.com/blogortopedia/escaras-o-ulceras-por-presion/.es_ES
dc.source.bibliographicCitationShe, Jinhua, Sho Yokota, y Eliza Yingzi Du. 2013. «Automatic Heart-Rate-Based Selection of Pedal Load and Control System for Electric Cart». Mechatronics 23 (3): 279-88. https://doi.org/10.1016/j.mechatronics.2012.12.005.es_ES
dc.source.bibliographicCitationSinclair, Pj, Gm Davis, Rm Smith, Bs Cheam, y Jr Sutton. 2009. «Pedal Forces Produced during Neuromuscular Electrical Stimulation Cycling in Paraplegics». Clinical Biomechanics 11 (1): 51-57. https://doi.org/10.1016/0268-0033(95)00030-5.es_ES
dc.source.bibliographicCitationTiwari, P.S., L.P. Gite, M.M. Pandey, y A.K. Shrivastava. 2011. «Pedal Power for Occupational Activities: Effect of Power Output and Pedalling Rate on Physiological Responses». International Journal of Industrial Ergonomics 41 (3): 261-67. https://doi.org/10.1016/j.ergon.2011.02.011.es_ES
dc.source.bibliographicCitation«verNormaPDF.pdf». s. f.es_ES
dc.description.degreenameIngeniero(a) Mecánico(a)es_ES
dc.description.degreelevelPregradoes_ES
dc.publisher.facultyFacultad de Ingeniería Mecánica, Electrónica y Biomédicaes_ES
dc.description.notesPresenciales_ES
dc.creator.cedula1.075.295.594es_ES
dc.publisher.campusNeiva Buganviles-
Aparece en las colecciones: Ingeniería mecánica

Ficheros en este ítem:
Fichero Tamaño  
2020_CamiloAndresValenciaCórdoba_Autorización
  Restricted Access
573.06 kBVisualizar/Abrir  Request a copy
2020_CamiloAndrésValenciaCórdoba2.15 MBVisualizar/Abrir
2020_CamiloAndresValenciaCórdoba_Anexo190.01 kBVisualizar/Abrir
2020_CamiloAndrésValenciaCórdoba_Anexo72.69 kBVisualizar/Abrir
2020_CamiloAndrésValenciaCórdobaAnexo377.58 kBVisualizar/Abrir
2020_CamiloAndrésValenciaCórdobaAnexo473.41 kBVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons