Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.uan.edu.co/handle/123456789/2594
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Orta, Eleonora | - |
dc.contributor.advisor | Barraza, Jose | - |
dc.creator | Mosquera Zuñiga, Yissier | - |
dc.creator | Ramirez Lizca, Marlon Alberto | - |
dc.date.accessioned | 2021-03-03T21:18:41Z | - |
dc.date.available | 2021-03-03T21:18:41Z | - |
dc.date.created | 2020-06-06 | - |
dc.identifier.uri | http://repositorio.uan.edu.co/handle/123456789/2594 | - |
dc.description.abstract | This research assumed as its main objective to create a small-scale mechanism that produced water from the humidity of the air, with this prototype it was sought to mitigate the scarcity of the liquid in some sectors of the city of Santa Marta since the water supply It is not constant and thus contribute to the problem of this population. This process of water collection becomes the basis of the cooling cycle, where its main function is to cool an air stream in the evaporator until it reaches the point temperature. from dew to condensation of air humidity. The results obtained during the research resulted in the collection of 1,186 liters of water at an average ambient temperature of 27 to 30ºC at an average relative humidity of 70 to 87% for 15 hours, data that was taken during the tests and with the help of a digital hygrometer with an external sensor. | es_ES |
dc.description.tableofcontents | Esta investigación asumió como objetivo principal crear un mecanismo a pequeña escala que permitió captar agua a partir de la humedad del aire, con este prototipo se buscó una alternativa para mitigar la escasez del líquido en algunos sectores de la ciudad de Santa marta ya que el suministro de agua no es constante y de esta manera contribuir en la problemática a esta población. Este proceso de captación de agua se logró en base al ciclo de refrigeración, donde su función principal fue enfriar una corriente de aire en el evaporador hasta alcanzar la temperatura de punto de rocío hasta condensar la humedad del aire, los resultados obtenidos durante el proceso de investigación dio como resultado la captación de 1,186 litros de agua a una temperatura ambiente promedio de 27 a 30ºC a una humedad relativa promedio del 70 a 87% durante 15 horas, datos que fueron tomados durante las pruebas y con la ayuda de un higrómetro digital con sensor externo. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad Antonio Nariño | es_ES |
dc.rights | Atribución 3.0 Estados Unidos de América | * |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/us/ | * |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.subject | Condensación | es_ES |
dc.subject | punto roció | es_ES |
dc.subject | humedad relativa | es_ES |
dc.subject | temperatura. | es_ES |
dc.title | Obtención de Agua Mediante Condensación de la Humedad del Aire de la Ciudad de Santa Marta | es_ES |
dc.publisher.program | Tecnología en Mantenimiento Electromecánico Industrial (Distancia) | es_ES |
dc.rights.accesRights | openAccess | es_ES |
dc.subject.keyword | Condensation | es_ES |
dc.subject.keyword | dew point | es_ES |
dc.subject.keyword | relative | es_ES |
dc.subject.keyword | humidity | es_ES |
dc.subject.keyword | temperature | es_ES |
dc.type.spa | Trabajo de grado (Pregrado y/o Especialización) | es_ES |
dc.type.hasVersion | info:eu-repo/semantics/acceptedVersion | es_ES |
dc.source.bibliographicCitation | [1] O. G. Gómez-Duarte, «Contaminación del agua en países de bajos y medianos recursos, un problema de salud pública,» Revista de la Facultad de Medicina, 2018. | es_ES |
dc.source.bibliographicCitation | [2] D. &. M. I. Beysens, «The case for alternative fresh water sources,» Pour les resources alternatives en eau, Secheresse, 2000. | es_ES |
dc.source.bibliographicCitation | [3] Marroquín ,Felipe «Samarios se quejan por mal estado del agua que reciben,» 16 Marzo 2020. | es_ES |
dc.source.bibliographicCitation | [4] B. Velázquez Martí, Conceptos fundamentales de psicrometría, 2018. | es_ES |
dc.source.bibliographicCitation | [5] F. J. Gálvez, Curso teórico practico de fundamentos fisicos de la ingeniería, 1998. | es_ES |
dc.source.bibliographicCitation | [6] D. Lide, « CRC Manual de Química y de Física,» CRC Press, 1992. | es_ES |
dc.source.bibliographicCitation | [7] F. P. Incropera, Fundamentos de transferencia de calor, México: Prentice Hall, 1999. | es_ES |
dc.source.bibliographicCitation | [8] C. V. Calahorro, Química general: introducción a la química teórica, 1995. | es_ES |
dc.source.bibliographicCitation | [9] Ç. Yunus A, Temodinámica, 6ta edición, Mc Graw Hil, 2009. | es_ES |
dc.source.bibliographicCitation | [10] M. R. Ortega, Lecciones de Física (4 volúmenes), Monytex, 1989-2006. | es_ES |
dc.source.bibliographicCitation | [11] S. Pezzotti, Estudio experimental del efecto Magnus en cuerpos cilíndricos de secciones transversales diversas, (Doctoral dissertation, Universidad Nacional de La Plata), 2016. | es_ES |
dc.source.bibliographicCitation | [12] C. A. P. B. &. E. B. Camargo Gonzalez, Sistema de Generación de Agua Mediante Humedad del Aire. | es_ES |
dc.source.bibliographicCitation | [13] L. Huertas, «El control ambiental en invernaderos: humedad relativa,» Hortícola, nº 205, pp. 52-54, 2008. | es_ES |
dc.source.bibliographicCitation | [14] E. &. L. L. Martines, «Cálculo de la Temperatura de Punto de Rocío a Diferentes Valores de Presión,» Centro Nacional de Metrología, 2008. | es_ES |
dc.source.bibliographicCitation | [15] W. C. &. J. W. M. Whitman, Tecnología de la refrigeración y aire acondicionado (Vol. 3), Editorial Paraninfo, 2000. | es_ES |
dc.source.bibliographicCitation | [16] P. B. J. CARLOS, «REFRIGERACIÓN POR COMPRESIÓN DE VAPOR». | es_ES |
dc.source.bibliographicCitation | [17] M. d. S. Publica, Decreto 475 de 1998, Colombia. | es_ES |
dc.source.bibliographicCitation | [18] A. Sacristán Gómez, Obtención de agua a partir de humedad atmosférica empleando células de efecto Peltier, 2011. | es_ES |
dc.source.bibliographicCitation | [19] C. A. &. B. P. B. E. Camargo Gonzalez, Sistema de generación de agua mediante humedad del aire. | es_ES |
dc.source.bibliographicCitation | [20] A. L. T.-S. J. L. P.-V. O. L. &. M.-V. O. R. Bautista-Olivas, La humedad atmosférica como fuente opcional de agua para uso doméstico, 2011. | es_ES |
dc.source.bibliographicCitation | [21] A. K. Biswas, «Agua para el mundo en desarrollo en el siglo XXI: temas e implicaciones,» Tecnología y ciencias del agua, 2015. | es_ES |
dc.source.bibliographicCitation | [22] R. F. C. C. &. B. L. P. Hernández Sampieri, Metodología de la investigación, 2010. | es_ES |
dc.description.degreename | Tecnólogo(a) en Mantenimiento Electromecánico Industrial | es_ES |
dc.description.degreelevel | Tecnológica | es_ES |
dc.publisher.faculty | Facultad de Ingeniería Mecánica, Electrónica y Biomédica | es_ES |
dc.description.notes | Distancia | es_ES |
dc.creator.cedula | 1045020133 | es_ES |
dc.creator.cedula | 1083041594 | es_ES |
dc.publisher.campus | Santa Marta | - |
Aparece en las colecciones: | Tecnología en mantenimiento electromecánico industrial |
Ficheros en este ítem:
Fichero | Tamaño | |
---|---|---|
2020YissierMosqueraZuñigaMarlonAlbertoRamirezLizcano.pdf | 2.75 MB | Visualizar/Abrir |
2020AutorizaciondeAutores.pdf Restricted Access | 350.85 kB | Visualizar/Abrir Request a copy |
2020AutorizaciondeAutores2.pdf Restricted Access | 219.26 kB | Visualizar/Abrir Request a copy |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons