Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.uan.edu.co/handle/123456789/3126
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRojas Moreno, Omar Franklin-
dc.creatorCorredor Pineda, Jesús Alberto-
dc.date.accessioned2021-03-10T18:12:17Z-
dc.date.available2021-03-10T18:12:17Z-
dc.date.created2020-11-25-
dc.identifier.urihttp://repositorio.uan.edu.co/handle/123456789/3126-
dc.descriptionPropiaes_ES
dc.description.abstractAcerías Paz del Rio Company has a plant named “Laminación 450”, there is a pneumatic system with about 70 years of installation, which is currently composed with 3 compressors of the Kaeser mark, each of them has a power of 250 hp, There are drawbacks due to the large volumes of condensate liquid, that appear in valves, pipes, cylinders, and in the final product itself, this happens since there are no dryers and an adequate drainage system, in addition there are considerable leaks that generate falls pressure and additional consumption of electrical energy for the operation of the compressors. After having initially installed the pneumatic network, it has been possible to establish that from the maintenance part of the company, it has not been given enough importance to improve its operation, for this reason a study was carried out in which establish actions that will contribute to reducing the consumption of electrical energy for the operation of the compressors, and therefore a considerable economic saving, the amount of condensate that is being generated was clearly established and the equipment that when installed will considerably reduce the impact of this in the final consumers and in the facilities, as well as that these go according to the required air quality established in the ISO8573-1 standard. Keywords: (Redesign, Energy Saving, Compressed Air, Compressor, Condensate)es_ES
dc.description.sponsorshipOtroes_ES
dc.description.tableofcontentsEn la planta Laminación 450 de la empresa Acerías Paz del Rio, se cuenta con una red neumática con cerca de 70 años de instalación, la cual está compuesta actualmente por 3 compresores marca Kaeser, cada uno de ellos tiene una potencia de 250 hp, allí se presentan inconvenientes debido a los grandes volúmenes de condensado que aparecen en válvulas, tuberías, cilindros, y en el mismo producto final, esto sucede ya que no se cuenta con secadores y un sistema adecuado de drenajes, además se presentan fugas considerables que generan caídas de presión y un consumo adicional de energía eléctrica para el funcionamiento de los compresores. Luego de haber sido instalada inicialmente la red neumática, se ha podido establecer que desde la parte de mantenimiento de la empresa , no se le ha dado la suficiente importancia para mejorar el funcionamiento de esta, por tal motivo se realizó un estudio en el cual se establecen acciones que contribuirán a reducir el consumo de energía eléctrica para la operación de los compresores, y por lo tanto un ahorro económico considerable, se estableció claramente la cantidad de condensado que se está generando y los equipos que al ser instalados reducirán considerablemente el impacto de este en los consumidores finales y en las instalaciones, así como también que estos vayan acordes a la calidad del aire requerido establecido en la norma ISO8573-1. Palabras clave: (Rediseño, Ahorro Energético, Aire Comprimido, Compresor, Condensado)es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.subjectRediseño, Ahorro Energético, Aire Comprimido, Compresor, Condensadoes_ES
dc.titleRediseño de red neumática en empresa Acerías paz del rio planta laminación 450es_ES
dc.publisher.programIngeniería Electromecánicaes_ES
dc.rights.accesRightsrestrictedAccesses_ES
dc.subject.keywordRedesign, Energy Saving, Compressed Air, Compressor, Condensatees_ES
dc.type.spaTrabajo de grado (Pregrado y/o Especialización)es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.source.bibliographicCitation(1) (DOC) Aire comprimido -Características -Tipos de compresores | JOFRE TITUAÑA - Academia.edu. (s. f.). Recuperado 22 de noviembre de 2020, de https://www.academia.edu/29690542/Aire_comprimido_Caracter%C3%ADsticas_Tipos_de_compresoreses_ES
dc.source.bibliographicCitationAguilar, E. F. (2014). La ley de Boyle, Boyke: Bajo presión. RBA Coleccionables.es_ES
dc.source.bibliographicCitationAgustin, V. N., Jose Pedro. (2005). Apuntes de Fisica General. UNAM.es_ES
dc.source.bibliographicCitationCassani, M. A. (s. f.). Aire comprimido el fluido vital de las máquinas. 15.es_ES
dc.source.bibliographicCitationCollieu, A. M., & Powney, D. J. (1977). Propiedades mecanicas y termicas de los materiales. Reverte.es_ES
dc.source.bibliographicCitationCopco, A. (s. f.). ISO 8573-1, ¿Cómo interpretamos la norma? Atlascopco. Atlas Copco. Recuperado 22 de noviembre de 2020, de https://www.atlascopco.com/es-es/compressors/air-compressor-blog/iso-8573-1-como-interpretamos-la-normaes_ES
dc.source.bibliographicCitationEnergia Neumatica. (s. f.). calameo.com. Recuperado 22 de noviembre de 2020, de https://www.calameo.com/books/001823905c6596c72c055es_ES
dc.source.bibliographicCitationIntroduccion a la Mecanica de Fluidos. (s. f.). Univ. Nacional de Colombia.es_ES
dc.source.bibliographicCitationLa importancia de auditar la calidad del aire comprimido según la ISO 8573-1. (s. f.). Interempresas. Recuperado 22 de noviembre de 2020, de https://www.interempresas.net/Seguridad-Alimentaria/Articulos/264423-La-importancia-de-auditar-la-calidad-del-aire-comprimido-segun-la-ISO-8573-1.htmles_ES
dc.source.bibliographicCitationLeonardo, J. C. y. (1858). Constancia de la composición quimica del aire: Discurso pronunciado ante el Claustro de la Universidad Central. Imp. del Colegio de Sordo-mudos y de Ciegoses_ES
dc.source.bibliographicCitationMarta, M. D., & José, R. D. A. A. (2016). MÁQUINAS Y MOTORES TÉRMICOS: INTRODUCCIÓN A LOS MOTORES ALTERNATIVOS Y A LAS TURBOMÁQUINAS TÉRMICAS. Editorial UNED.es_ES
dc.source.bibliographicCitationSalvador, A. G. (1988). Introducción a la Neumática. Marcombo.es_ES
dc.source.bibliographicCitationSolé, A. C. (2012). Neumatica e Hidráulica. Marcombo.es_ES
dc.source.bibliographicCitationTubo neumático. (2020). En Wikipedia, la enciclopedia libre. https://es.wikipedia.org/w/index.php?title=Tubo_neum%C3%A1tico&oldid=130305883es_ES
dc.source.bibliographicCitationWark, K., & Warner, C. F. (1990). Contaminación del aire: Origen y control. Limusa.es_ES
dc.source.bibliographicCitationWentworth, W. E., & Ladner, S. J. (1975). Fundamentos de química física. Reverte.es_ES
dc.source.bibliographicCitationZhang, B., Liu, M., Li, Y., & Wu, L. (2013). Optimization of an Industrial Air Compressor System. Energy Engineering, 110(6), 52-64. https://doi.org/10.1080/01998595.2013.10753695es_ES
dc.source.bibliographicCitationOptimization of an industrial Air Compressor System, Energy engineering. Volumen 110: Issue 6 (2013); pp 52-64 -- Taylor & Francises_ES
dc.source.bibliographicCitationYunus A. Cengel, Michael A. Boles. TERMODINÁMICA. Ed. Mc Graw Hill 4ta Edición, México, 2003es_ES
dc.source.bibliographicCitationAhorro de energía en los sistemas neumáticos industriales , Tesis para optar por el título de Maestro en Ciencias en sistemas para manufactura , Héctor Manuel Corona Gómez https://repositorio.tec.mx/bitstream/handle/11285/568432/DocsTec_6131.pdf?sequence=1&isAllowed=yes_ES
dc.source.bibliographicCitationEnergy Tips. DETERMINE THE COST OF COMPRESSED AIR FOR YOUR PLANT. Office of Industrial Technologies Energy Efficiency and Renewable Energy U.S. Department of Energy Washington, D.C. 20585, https://www.nrel.gov/docs/fy01osti/28006.pdfes_ES
dc.source.bibliographicCitationCarnicer, E. (1991). Aire Comprimido Teoría y Cálculo de las instalaciones. Madrid: paraninfoes_ES
dc.source.bibliographicCitationCompressed Air Optimization in Switzerland, Springer Link, Rolf Gloor, Christian Bachmann in Energy Efficiency in Motor Driven Systems (2003), https://link.springer.com/chapter/10.1007/978-3-642-55475-9_3es_ES
dc.source.bibliographicCitationOptimization of integrated energy process in China industrial compressed air system https://www.sciencedirect.com/science/article/pii/B9781782421696500115?via%3Dihub Compressed Aires_ES
dc.source.bibliographicCitationCompressed Air System Installation Guide, Layout considerations for a Reliable, Energy Efficient, and Safe Compressed Air System, (consultado 09, Julio, 2020) https://co.kaeser.com/recursos-de-aire-comprimido/descargas/libro-electronico/casig.aspxes_ES
dc.source.bibliographicCitationParker Domnick Hunter KG (consultado 03, Julio, 2020) Introducción a las normas ISO de calidad del aire https://www.oga.com.co/ogaen/wp-content/uploads/2015/08/ANEXO-1-CALIDAD-DE-AIRE-NORMA-ISO.pdfes_ES
dc.source.bibliographicCitationHandbook of Mechanical Engineering Calculations, Second Edition, Compressor selection for compressed –air systems, (consultado 26, Julio, 2020) https://ezproxy.uan.edu.co:2107/content/book/9780071458863/toc-chapter/chapter9/section/section12es_ES
dc.source.bibliographicCitationEl agua en la atmosfera (consultado 14, Mayo, 2020) https://www.amc.edu.mx/revistaciencia/index.php/ediciones-anteriores/77-vol-58-num-3-julio-septiembre-2007/agua/117-el-agua-en-la-atmosferaes_ES
dc.source.bibliographicCitationCálculo de la temperatura de punto de roció a diferentes valores de presión, Enrique Martínez L, Leonel Lira C. Centro Nacional de Metrología, (consultado 13, Agosto,, 2020) https://www.academia.edu/35604938/C%C3%A1lculo_de_la_Temperatura_de_Punto_de_Roc%C3%ADo_a_Diferentes_Valores_de_Presi%C3%B3nes_ES
dc.source.bibliographicCitationDiseño y construcción de un prototipo de secador de aire comprimido 230 𝑚3/ℎ según los requerimientos de la empresa “COMPAIRGEN” de la Ciudad de Quito, Tesis para la obtención del título de Ingeniero Mecánico, año 2016, (consultado 10, Julio, 2020) http://192.188.46.193/bitstream/123456789/23070/1/Tesis%20I.M.%20333%20-%20Vega%20Gonz%C3%A1lez%20Leonardo%20Israel.pdfes_ES
dc.source.bibliographicCitationCálculo y selección de un sistema de tratamiento de aire comprimido para la red neumática del laboratorio de automatización de la facultad tecnológica, Universidad Francisco José de Caldas(consultado 03, Julio, 2020) http://repository.udistrital.edu.co/bitstream/11349/15691/1/Herre%C3%B1oPe%C3%B1aDiegoAlejandro2019.pdfes_ES
dc.source.bibliographicCitationKaeser Compresores, (consultado 07, Julio, 2020) Volumen adecuado del tanque de almacenamiento para garantizar el tiempo de servicio estimado de las unidades de compresión https://airecomprimidokaeser.com/index.php/2016/02/15/volumen-adecuado-del-tanque-de-almacenamiento/es_ES
dc.description.degreenameIngeniero(a) Electromecánico(a)es_ES
dc.description.degreelevelPregradoes_ES
dc.publisher.facultyFacultad de Ingeniería Mecánica, Electrónica y Biomédicaes_ES
dc.description.funderPropiaes_ES
dc.description.notesDistanciaes_ES
dc.creator.cedula1052396275es_ES
dc.publisher.campusTunja-
Aparece en las colecciones: Ingeniería electromecánica

Ficheros en este ítem:
Fichero Tamaño  
2020JesúsAlbertoCorredorPineda .pdf2.51 MBVisualizar/Abrir
2020AutorizaciòndeAutores.pdf
  Restricted Access
110.71 kBVisualizar/Abrir  Request a copy


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons