Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.uan.edu.co/handle/123456789/5883
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorQuintero Ortega, Carlos Alberto-
dc.contributor.advisorSuárez Gélvez, Blanca Lynne-
dc.creatorOrtiz Hernández, Darlin Yulieth-
dc.creatorQuintero Ortega, Juan Sebastián-
dc.date.accessioned2022-02-15T22:34:59Z-
dc.date.available2022-02-15T22:34:59Z-
dc.date.created2021-06-04-
dc.identifier.urihttp://repositorio.uan.edu.co/handle/123456789/5883-
dc.description.abstractIn this investigation, a comparison was made between 2 curing lamps in the depth of cure of a nanohybrid resin of enamel and dentin. The lamp that offered the greatest depth of curing of the Forma Ultradent resin was the Valo, observing a statistically significant difference of (p <0.05) giving minimum values of 1.65mm in dentin and 2.85mm in enamel; maximum values of 1.90mm dentin and 3.0 enamel compared to the conventional minimum values of 1.65mm dentin and 2.60mm enamel; maximum values of 1.74mm dentin and 2.82mm enamel.es_ES
dc.description.tableofcontentsEn esa investigación se realizó una comparación entre 2 lámparas de fotocurado en la profundidad de curado de una resina nanohibrida de esmalte y dentina. La lámpara que ofreció mayor profundidad de curado de la resina Forma Ultradent fue la Valo observándose una diferencia estadísticamente significativa de (p < 0.05) dando unos valores mínimos de 1,65mm en dentina y 2,85mm esmalte; unos valores máximos de 1,90mm dentina y 3,0 esmalte frente a la convencional con valores mínimos de 1,65mm dentina y 2,60mm esmalte; valores máximos de 1,74mm dentina y 2,82mm esmalte.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.subjectFotocuradoes_ES
dc.subjectValoes_ES
dc.subjectLámpara convencionales_ES
dc.subjectresina nanohibridaes_ES
dc.titleComparación de dos lámparas de fotocurado de luz led convencional vs valo en la profundidad de curado en un sistema resinoso forma-ultradentes_ES
dc.typeTesis - Trabajo de grado - Monografia - Pregradoes_ES
dc.publisher.programOdontologíaes_ES
dc.rights.accesRightsopenAccesses_ES
dc.subject.keywordCuringes_ES
dc.subject.keywordValoes_ES
dc.subject.keywordConventional lampes_ES
dc.subject.keywordNanohybrid resines_ES
dc.type.spaTrabajo de grado (Pregrado y/o Especialización)es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.source.bibliographicCitationAcosta C. y Bilbao J. (2001). Equipos de fotocurado. Acta Odontológica Venezolana, 39(2): 76-80.es_ES
dc.source.bibliographicCitationAmôedo, M., Braga, L., Tarkany, R., Botelho, F. y Gomes, F. (2016). Longevity of restorations in direct composite resin: literature review. Revista Gaúcha de Odontología, Porto Alegre, 64(3): 320-326.es_ES
dc.source.bibliographicCitationArmellin, E., Bovesecchi, G., Coppa, P., Pasquantonio, G. y Cerroni, L. (2016). LED Curing Lights and Temperature Changes in Different Tooth Sites. BioMed Research International, doi: 10.1155/2016/1894672.es_ES
dc.source.bibliographicCitationCardoso, I., Machado, A., Teixeira, D., Basílio, F., Marletta, A. y Soares, P. (2019). Influence of Different Cordless Light-emitting-diode Units and Battery Levels on Chemical, Mechanical, and Physical Properties of Composite Resin. Operative Dentistry, 45(4):377-386.es_ES
dc.source.bibliographicCitationCarrillo, C. Monroy, M. (2009). Materiales de resinas compuestas y su polimerización. Revista Asociación Dental Americana. 65(4): 10-17.es_ES
dc.source.bibliographicCitationChaple, A., Montenegro, Y. y Álvarez, J. (2016). Evolución histórica de las lámparas de fotopolimerización. Revista Habanera de Ciencias Médicas, 15(1):8-16.es_ES
dc.source.bibliographicCitationCohelo, U., Montenegro, A., Zander, F., Cruz, G., Zander, C., Sergio, G. y Hilgemberg, P. (2018). Avaliação do grau de conversão monomérica de resinas compostas ortodônticas. Orthodontic Science and Practice 11(41):28-32.es_ES
dc.source.bibliographicCitationDaugherty, M. , Lien, W., Mansell, M., Risk, D., Savett, D. y Vandewalle, K. (2018). Effect of High-Intensity Curing Lights on the Polymerization of Bulk-Fill Composites. Dental Materials, 34(10):1531‐1541.es_ES
dc.source.bibliographicCitationDiscacciati, A., Discacciati, J., Lambert, R. y Corrêa, W. (2002). Correlação entre grau de conversão, microdureza e conteúdo inorgânico em compósitos. Pesquisa Odontológica Brasileira, 16(4):349-354.es_ES
dc.source.bibliographicCitationFadul, J., Molina, C., Yáñez, E. y Luna, L. (2008). Profundidad de curado de resinas con diferentes fotoiniciadores polimerizadas con dos lámparas LED. Universitas Odontológicas, 27(59): 15-22.es_ES
dc.description.degreenameOdontólogo(a)es_ES
dc.description.degreelevelPregradoes_ES
dc.publisher.facultyFacultad de Odontologíaes_ES
dc.audienceGenerales_ES
dc.description.notesPresenciales_ES
dc.creator.cedula20571628558es_ES
dc.creator.cedula20571622924es_ES
dc.publisher.campusCúcutaes_ES
dc.description.degreetypeInvestigaciónes_ES
Aparece en las colecciones: Odontología

Ficheros en este ítem:
Fichero Tamaño  
2021_DarlynOrtiz19.29 MBVisualizar/Abrir
2021_DarlynOrtiz_Acta
  Restricted Access
419.09 kBVisualizar/Abrir  Request a copy
2021_DarlynOrtiz_Autorización1
  Restricted Access
447.71 kBVisualizar/Abrir  Request a copy
2021_DarlynOrtiz_Autorización2
  Restricted Access
510.56 kBVisualizar/Abrir  Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.